An Analysis of the Selection of Riser Diameters in Firefighting Water-Supply Systems in High-Rise Buildings
Journal Title: Safety & Fire Technology - Year 2017, Vol 46, Issue 46
Abstract
Aim: This article is aimed at analysing the validity of the selection of diameters for risers in the water-supply systems of high-rise buildings, on the basis of the regulations in force. Central focus was placed on the analysis of the throughput characteristics, accounting for their dimensions and materialrelated solutions. Introduction: The article addresses the problems of requirements and the selection of diameters for risers in the water-supply systems of high-rise buildings. The regulations impose the use of risers with specific diameters, considered to meet the minimum requirements. In order to elaborate on whether the nominal diameters (DN) can be justified by their throughput properties and whether the use of smaller-diameter risers will contribute to substantial pressure losses, pressure drops in water-supply pipes were calculated. On the basis of the analysis, conclusions were formulated and grounds were presented for the amendment of regulations governing minimum riser diameters in high-rise buildings. Methodology: The article was prepared on the basis of the calculations of pressure drops in water-supply conduits. The results of the calculations were compared for various diameters of risers made of galvanised steel pipes and smooth (copper) pipes. Two calculating methods were applied: utilising (1) the Darcy-Weisbach equation and (2) the Hazen-Williams equation. Results: A conclusion to be derived from the comparison between the pressure losses calculated for the DN 65 and DN 80 risers is that differences in the prescribed throughput values, if any, are negligible. This thesis seems to be confirmed by the results obtained in both calculation methods. Conclusions: The calculations corroborated the thesis that the DN 80 risers in high-rise buildings can effectively be replaced by risers utilising DN 65 diameters. At a flow of 5 dm3 /s, the difference between pressure losses along a 100 m section is approx. 0.3 bar. The DN 80 diameter unnecessarily increases the costs of materials and manufacturing and the burden of installation. It is advisable in respect of certain (e.g. residential) buildings that the installation-efficiency requirements be relaxed (this also applies to systems fitted with Ø33 hydrants). This would allow the use of DN 50 risers in these buildings, without compromising the safety level. In order to be introduced, the proposed changes would require the amending of the regulations in force, in particular, the Regulation of the Minister of the Interior and Administration on the fire protection of buildings, other civil structures and areas (Journal of Laws No. 109, item 719) in the part relating to water-supply systems in high-rise buildings.
Authors and Affiliations
mł. bryg. dr inż. Tomasz Drzymała, Sylwester Kieliszek, Joanna Binio
Новые требования к пожарным сигнализаторам дыма
Цель: Целью статьи является показать запаздывание процесса стандартизации в области пожарных сигнализаторов дыма от реального уровня техники в этом направлении; выявить ошибки и неточности в тексте проекта стандарта prEN...
A Model of a Firefighter’s Thermal Condition when Attired in Protective Clothing
Aim: The purpose of this study is to develop and verify a mathematical model, which identifies the thermal condition of a firefighter whilst wearing heat protective clothing at different temperature levels. The model is...
Long-Term Variability of Forest Fires in Selected 28 European Countries, Canada and the USA
Aim: The primary aim of this paper was to determine long-term variability in the number of forest fires and burnt forest area in selected 28 European countries, Canada and the USA and to assess the effectiveness of fir...
Wybuch zbiornika ze sprężonym gazem palnym jako czynnik ryzyka zawodowego strażaka
Cel: Artykuł podejmuje temat rozpoznania poziomu ryzyka, jakie w pracy strażaka-ratownika jest związane z wybuchem zbiornika/butli ze sprężonym gazem palnym podczas pożaru. Wprowadzenie: Jednym ze zjawisk powodującyc...
The Basic Elements of Medical Safety and the Functioning of the Medical Component of the State Fire Service During the 2016 World Youth Days in Krakow
Aim: The aim of this study was to present how KOMED PSP was organised and what equipment it used. Introduction: Between 26 and 31 July 2016 Krakow hosted the 31st World Youth Day (WYD Krakow 2016). The programme of the e...