An Aptamer-based Biosensor for Troponin I Detection in Diagnosis of Myocardial Infarction
Journal Title: Journal of Biomedical Physics and Engineering - Year 2018, Vol 8, Issue 2
Abstract
Background: Acute myocardial infarction (MI) accounts for one third of deaths. Cardiac troponin I (TnI) is a reliable biomarker of cardiac muscle tissue injury and is employed in the early diagnosis of MI. Objective: In this study, a molecular method is introduced to early diagnosis of MI by rapid detection of TnI. Materials and Methods: The detection method was based on electrochemical aptasensing, being developed using different methods and evaluation steps. A gold electrode was used as a transducer to successful immobilize 76base aptamer to fabricate a TnI biosensor. Results: The designed aptasensor could detect TnI in a range of 0.03 to 2.0 ng mL-1 without using any label, pre-concentration or amplification steps. The limit of detection was attained as 10 pg mL-1 without significant trouble of interfering species. The TnI biosensor demonestrated a stable, regenerative and reproducible function. 89 human samples were used to evaluate the performance of the TnI biosensor, and it represented 100% and 81%, diagnostic sensitivity and specificity, respectively. Conclusion: This aptasensor may be used as an applicable tool in the future of early medical diagnosis of MI.
Authors and Affiliations
M. Negahdary, N. Sattarahmady, H. Heli
Investigating the Impact of Knee Prosthesis in Patients’ Body on Radiation Dose Distribution: A Monte Carlo Approach
Background: Metal prostheses in patients affect the radiotherapy dose distribution. Metal prostheses with high density and atomic number cause major changes in scattering and attenuation of radiation. The present study a...
Differentiation of Edematous, Tumoral and Normal Areas of Brain Using Diffusion Tensor and Neurite Orientation Dispersion and Density Imaging
Background: Presurigical planning for glioma tumor resection and radiotherapy treatment require proper delineation of tumoral and peritumoral areas of brain. Diffusion tensor imaging (DTI) is the most common mathematical...
Evaluation of AAA and XVMC Algorithms for Dose Calculation in Lung Equivalent Heterogeneity in Photon Fields: A Comparison of Calculated Results with Measurements
Aims: The aims of the present work are (1) to evaluate dose calculation accuracy of two commonly used algorithms for 15 MV small photon fields in a medium encompassing heterogeneity and (2) to compare them with measured...
Assessment of Neutron Contamination Originating from the Presence of Wedge and Block in Photon Beam Radiotherapy
Background: One of the main causes of induction of secondary cancer in radiation therapy is neutron contamination received by patients during treatment. Objective: In the present study the impact of wedge and block on ne...
A Monte Carlo Study on the Effect of Various Neutron Capturers on Dose Distribution in Brachytherapy with 252Cf Source
Background: In neutron interaction with matter and reduction of neutron energy due to multiple scatterings to the thermal energy range, increasing the probability of thermal neutron capture by neutron captures makes dose...