An Ascending Aortic Haemodynamic Comparison Between Normotensive and Hypertensive Subjects
Journal Title: International Journal of Medical and Dental Sciences - Year 2013, Vol 2, Issue 1
Abstract
Background: Systemic hypertension, a common disorder with potentially serious complications, exerts ill effects through structural and functional modifications of arterial wall. Haemodynamics play an important role in the development of atherosclerosis. Local hemodynamic temporal pressure and wall shear stress are important for understanding the mechanisms leading to various complications in cardiovascular function. Objectives: Since we could not find such a study in literature involving Indian population, this prompted us to investigate and establish the relationship between the blood pressure and the ascending aortic pulse wave parameters in normal individuals and compare the same with hypertensives. Material and Methods: A case control study was done in a tertiary care hospital involving 25 hypertensive parents and further compared with 25 normotensive subjects of same age group acting as control. The GE ΜΆ P 100 Doppler echocardiography machine was used to study acceleration time, deceleration time, ejection time, ejection fraction, peak flow velocity and pressure gradient in hypertensives and compared the same with age matched normotensive. Also ascending aortic diameter was mapped at the annulus. Results: The results of our study confirmed our assumption that in hypertensive the ascending aortic haemodynamic parameters are abnormal and both systolic and diastolic blood pressure does exert a statistically significant influence on the Doppler parameters of ascending aorta. The acceleration time, deceleration time, pressure gradient and ejection time showed statistically significant increase in hypertensives when compared to normotensive. At the same time the ejection fraction and the ascending aortic diameter showed a statistically significant decrease than normotensive. Conclusion: We would conclude to say that the Doppler parameters of ascending aortic blood flow are abnormal in hypertensives. This altered haemodynamics may lead to further ill effects by way of altered peripheral haemodynamics. This Doppler evaluation of ascending aortic blood flow can be developed as a clinical tool for evaluating hypertensives and assessing the benefit of treatment of hypertension.
A study to evaluate and compare right and left condylar discrepancy between centric relation and maximum intercuspation in three age groups
Background: Since discrepancy between centric relation and maximum intercuspation has been an area of interest for dental fraternity for decades, the study was conducted to expand the concepts of the same when age is tak...
A Study on Various Modalities of Surgical Management of Sigmoid Volvulus
Background: Worldwide incidence of sigmoid volvulus varies from 6-30%. In India the incidence varies from 11.8% in the west to 1.5 - 9.4 % in north and south India respectively, depending on the dietary constituents. The...
Prevalence of Weak D (Du) in Blood Donors in a Referral Teaching Hospital
Background: Rh D is the most important Blood Group antigen after ABO Blood group antigen for transfusion purpose. All negative blood units by routine methods must be tested to detect weak D using IAT method. When the tes...
Acquired Amegakaryocytic Thrombocytopenic Purpura - An Underdiagnosed Entity
Acquired Amegakaryocytic Thrombocytopenic Purpura (AATP) is a rare cause of thrombocytopenia presenting over a wide age group with symptoms of bleeding and bone marrow showing isolated absence of megakaryocytes in an oth...
Breast Feeding Practices in Infants of Rural Western Uttar Pradesh Region of India
Background: Breastfeeding is one of the most effective ways to ensure child health and survival. But globally only less than 40% of infants under six months of age are exclusively breastfed. Adequate breastfeeding counse...