An automated dispensing system for improving medication timing in the emergency department

Journal Title: World Journal of Emergency Medicine - Year 2012, Vol 3, Issue 2

Abstract

BACKGROUND: Numerous medical conditions require timely medication administration in the emergency department (ED). Automated dispensing systems (ADSs) store premixed common doses at the point-of-care to minimize time to administration, but the use of such automation to improved time to medication administration has not been studied. Since vancomycin is a commonly used empiric antimicrobial, we sought to quantify the effect of using an ADS on time to drug delivery in patients presenting to the ED. The study aimed to determine the efficacy of utilizing an ADS to improve time to administration of vancomycin and determine any negative effects on dosing appropriateness. METHODS: The institional review board approved the retrospective quality improvement study took place in a single, urban academic tertiary care ED with an annual census of 80 000. Study subjects were all patients receiving vancomycin for the management of sepsis between March 1 to September 30, 2008 and the same time period in 2009. The primary outcome was the proportion of patients who received vancomycin within one hour of bed placement and the secondary outcome was dosing appropriateness. RESULTS: Sixty-three patients had weight and dosing information available (29 before and 34 after intervention) and were included in the study. Before intervention, no patient received vancomycin in less than 60 minutes, while after intervention 14.7% of the patients received it in less than 60 minutes (difference in proportions 14.7%, 95% CI 0.39%-30.0%, P=0.04). A similar proportion of the patients received correct dosing before and after intervention (44.8% vs. 41.2%, difference in proportions 3.7%, 95% CI -20.0%-26.7%, P=0.770). CONCLUSION: The use of an ADS may improve the timing of medication administration in patients presenting to the ED without affecting dosing appropriateness.

Authors and Affiliations

Keywords

Related Articles

Infected aortic and iliac aneurysms:Clinical manifestations in the emergency departments of two hospitals in southern Taiwan, China

BACKGROUND: Accurate diagnosis of infected aortic and iliac aneurysms is often delayed, hampering timely treatment and potentially resulting in a fatal consequence. The aim of this study was to discover useful clinical f...

An incidental case of Wellens' syndrome in a community emergency department

Wellens' syndrome, also called left anterior descending (LAD) coronary T-wave syndrome, is a characteristic electrocardiographic (ECG) pattern suggestive of coronary artery disease in the preinfarction stage.[1–3] ECG ch...

The first four cases of successful NeoChord procedure in mainland China

BACKGROUND: Transapical off-pump NeoChord procedure is a novel minimally invasive surgical repair of degenerative mitral regurgitation (MR). Here, we report the first four cases of NeoChord procedure in patients with mit...

Circulating microRNAs as potential biomarkers for diagnosis of congenital heart defects

BACKGROUND: MicroRNAs are small non-coding RNAs of approximately 22 nucleotides in length, and play important regulatory roles in normal heart development and the pathogenesis of heart diseases. Recently, a few prospecti...

Current pre-hospital traumatic brain injury management in China

BACKGROUND: Traumatic brain injury (TBI) is associated with most trauma-related deaths. Secondary brain injury is the leading cause of in-hospital deaths after traumatic brain injury. By early prevention and slowing of t...

Download PDF file
  • EP ID EP472800
  • DOI -
  • Views 44
  • Downloads 0

How To Cite

(2012). An automated dispensing system for improving medication timing in the emergency department. World Journal of Emergency Medicine, 3(2), 102-107. https://europub.co.uk/articles/-A-472800