An Innovative Technique to Evaluate Quantitative Pupillary Light Reflex by Dynamic Pupillometry using Infrared Videography
Journal Title: Journal of Clinical and Diagnostic Research - Year 2019, Vol 13, Issue 4
Abstract
ABSTRACT Introduction: An innovative approach was designed to quantify the pupillary light reflex using infrared and white light illumination. This method is convenient to detect pupil edges, area and the diameter of pupil contour recorded in different ambient light conditions. Aim: To establish newer methodology, to quantify pupillary light reflex using image analysis. Materials and Methods: A standard web camera was modified as an Infrared camera to capture the real time pupil response to various intensities of illuminations. Pupillary response to a flash of light was video graphed and split into video frames. These images of the pupil thus obtained were subjected to an image analysing software. This methodology also provides a solution to exclude infra-red LED reflection within the pupil circle. The orientation of pupil within iris can be appreciated with this protocol. Results: The steps were tailored to measure various parameters of pupillary light reflex like minimum, maximum and mean pupil diameters. It also facilitates to calculate constriction and dilation velocities. The capture, cleavage and offline analysis of these video frames were done using all open source softwares. Conclusion: This simple, user-friendly, innovative technology can be used for quantifying the pupil response which can be used as an indicator for autonomic dysfunction.
Authors and Affiliations
AV Siva Kumar, R Padmavathi, KN Maruthy, B Sowjanya, K Mahesh Kumar
A Comparative Analysis of Master Casts Obtained using Different Surface Treatments on Impression Copings for Single Tooth Implant Replacement -An In vitro Study
Introduction: Minor rotation of impression coping secured in the impression is an avoidable error that needs to be minimized to ensure precise positioning of implant analog in master cast. Aim: The aim of the study was t...
Nurses' Awareness about Principles of Airway Suctioning
Introduction: Airway suctioning is one of the most common interventions for patients with respiratory disorders and having adequate knowledge in implementing this technique is quite crucial for nurses. Aim: To assess the...
Acute Hypersensitivity Reaction Related to use of Pantoprazole Lacking Cross-Reactivity with Omeprazole
ABSTRACT Proton Pump Inhibitors (PPIs) are widely used drugs for peptic ulcer and other acid related disorders those are rarely causing allergic reactions. Cross-reactivity between the various PPIs has been documented. I...
Variation of Platelet Indices among Patients with Diabetes Mellitus Attending Tertiary Care Hospital
ABSTRACT Introduction: Diabetes Mellitus (DM) is a pandemic health problem. It is considered as a prothrombotic state with enhanced platelet activity. The platelet activation may alter platelet morphology and function wh...
Ectopic Parathyroid Adenoma Presenting as a Mediastinal Mass
A parathyroid adenoma present in an ectopic site, in the anterior mediastinum, is a rare cause of persistent hyperparathyroidism. Though its occurrence in the mediastinum is unusual, existence has been noted in literatur...