Analiza przyczyn uszkodzenia stropu

Journal Title: Builder - Year 2017, Vol 241, Issue 8

Abstract

Analysis of the cause of damage of a reinforced concrete floor above a garage of a multi-storey residential building. Undertaking an accurate assessment of the effects of concrete shrinkage and required minimum shrinkage reinforcement of complex reinforced concrete constructions emphasizes the fact of being an exceedingly difficult issue to consider. The analysis below broaches this matter basing on the example of a fragment of a building characterized by a rare construction system. Since the shrinkage aspects have not been taken into account, the applied reinforcement concerns only bending. Indeed, this fact, as well as the peculiarity of a shape of the building, affected the ceiling surface causing the emergence of a crack across its length and thus, plenty of leaks. The study of the above- -mentioned case attempts to specify the quantity of required reinforcement by comparing results obtained from various methods adopted for this purpose.<br/><br/>

Authors and Affiliations

Marcelina Jakubczyk, Izabella Trochimiak

Keywords

Related Articles

Rewitalizacja szansą dla innowacyjnych dociepleń

W niniejszym artykule zarysowano stan obecny, uwarunkowania, szanse oraz bariery w odniesieniu do implementacji innowacyjnych i ekologicznych rozwiązań termomodernizacyjnych w Europie Zachodniej i w Polsce. Wskazano zaró...

Lekka obudowa w nadbudowach i renowacjach

W artykule przedstawiono możliwości wykorzystania technologii lekkiej obudowy do nadbudowy i renowacji obiektów budowlanych. Opisano kolejne kroki przygotowania inwestycji dotyczącej projektowania i realizacji nadbudowy...

Jaką strategię obrać? Część 2 Badania i analizy

Success in the construction industry is determined by the ability to develop and implement an aproppriate strategy. Due to the significant impact of construction on condition of the national economy, the comprehensive an...

Faktory opóźnień

Identification and rank of delay factors in construction projects depending on the project delivery system . The implementation of construction projects depends on many unpredictable factors, which can cause delays in co...

Architektura i przemysł. Część 3. Tendencje estetyczne.

Contemporary production plants are not designed to service the technology only, acting as a mere cladding (more on this in the previous parts of the series), but can also play an important representative role, acting as...

Download PDF file
  • EP ID EP641718
  • DOI -
  • Views 100
  • Downloads 0

How To Cite

Marcelina Jakubczyk, Izabella Trochimiak (2017). Analiza przyczyn uszkodzenia stropu. Builder, 241(8), 88-90. https://europub.co.uk/articles/-A-641718