Analysis of 12 Months Clinical Outcomes Associated with Implantation of Ultrathin (60 μm) Bare Metal Stent in an Unselected Real-world Population with Coronary Artery Disease

Journal Title: Journal of Clinical and Diagnostic Research - Year 2017, Vol 11, Issue 5

Abstract

Introduction: In the era of drug-eluting stents, Bare Metal Stent (BMS) has worked its way up to be recognized in several indications. Moreover, literature suggests that strut thickness has been directly related to the restenosis rate. Aim: We intended to evaluate the clinical performance of the ultrathin (60 μm) Flexinnium stent (Sahajanand Medical Technologies Pvt. Ltd. Surat, India) for treatment of a wide range of patients with coronary artery disease in routine clinical practice. Materials and Methods: This was an observational, nonrandomized, retrospective, single-arm study carried out in realworld patients at three clinical centres of India. A total of 419 consecutive patients’ data was collected for the study, who underwent treatment for coronary lesions by implantation of Flexinnium stent, between April 2013 and December 2014. The primary endpoint of the study was Major Adverse Cardiac Events (MACE), a conglomerate of cardiac death, Myocardial Infarction (MI) (Q-wave and non-Q-wave), Target Lesion Revascularization (TLR) and Target Vessel Revascularization (TVR). Any incidence of Stent Thrombosis (ST) was also observed as safety endpoint. These endpoints were observed during in-hospital stay, at 30 days, six months and at 12 months follow up. All data were analysed using the Statistical Package for Social Sciences (SPSS; Chicago, IL, USA) program, version 15. Results: A total of 491 lesions were treated in 419 patients having mean age of 54.1 years. A total of 525 Flexinnium stents were implanted. There were 243 (58.0%) patients with hypertension. At 12 months the total incidences of MACE were 14 (3.5%). These included 9 (2.3%) cardiac deaths, 1 (0.3%) MI, 3 (0.8%) TLRs and 1 (0.3%) TVR. There was one incidence of definite ST at 12 months follow up. Conclusion: Our results demonstrate that the Flexinnium stent is associated with a low 12 months incidence of MACE in a wide range of real-world population. Long-term follow up would further confirm its clinical performance profile.

Authors and Affiliations

Adikesava Naidu Otikunta, Uday Kumar Hosad, Y V Subba Reddy, Srikanth Eruvara, Ravi Sriniva, Rajeev Garg, Limmy Loret Lobo

Keywords

Related Articles

VCAM-1(rs3783605A>G) Single-Nucleotide Polymorphism Genotyping in a Sample of Type 2 Diabetes Mellitus Iraqi Patients

Introduction: The Vascular Adhesion Molecule-1 (VCAM-1) is a cell surface glycoprotein expressed by cytokine-activated endothelium, mediates the adhesion of monocytes and lymphocytes. Diabetes mellitus is a common global...

Sinus Rhythm in Rheumatic Mitral Stenosis after Balloon Mitral Valvotomy: Is it Feasible?

Introduction: Atrial Fibrillation (AF) is largely present in patients with rheumatic valvular disease, leading to hospitalizations. Aim: We aimed to study the restoration and maintenance of Sinus Rhythm (SR) in rheumatic...

A Review of Influenza Vaccination among Different Population Groups in Iran

ABSTRACT Annual influenza vaccination is the best means of prevention and control of influenza virus infection and its complications. Efforts to increase influenza vaccines coverage, especially in high-risk groups includ...

Radiographically Detectable Dystrophic Calcinosis of the Cheek: A Case Report and Literature Review

ABSTRACT Dystrophic calcinosis is a condition wherein calcium is deposited in degenerated tissues, often associated with trauma, infection, or inflammation, in the absence of a systemic mineral imbalance. It commonly occ...

The Effect of Training Intervention on Nurses’ Performance in Execution of Drug and Food Delivery via Nasogastric Tube

ABSTRACT Introduction: The safety of a patient who receives nutritional support by tube feeding depends on nursing care and proper implementation of method and detection by the nurse in case of potential damage threateni...

Download PDF file
  • EP ID EP342503
  • DOI 10.7860/JCDR/2017/24767.9896
  • Views 71
  • Downloads 0

How To Cite

Adikesava Naidu Otikunta, Uday Kumar Hosad, Y V Subba Reddy, Srikanth Eruvara, Ravi Sriniva, Rajeev Garg, Limmy Loret Lobo (2017). Analysis of 12 Months Clinical Outcomes Associated with Implantation of Ultrathin (60 μm) Bare Metal Stent in an Unselected Real-world Population with Coronary Artery Disease. Journal of Clinical and Diagnostic Research, 11(5), 12-16. https://europub.co.uk/articles/-A-342503