In seismic design building there are various methods to ensure stability against lateral forces caused by earthquake. Most commonly used systems is shear wall. The reinforcement concrete shear wall is one of the most reliable systems to make the structure resistant against lateral forces. Shear wall imparts stiffness to the structure which minimizes the damage caused by the earthquake and provides enough strength.. In this paper four models were analyzed in which two models are with shear wall and rest of two models are with shear wall for different heights. In shear wall models, shear wall are placed at corners. All 4 models with and without shear wall were analyzed through STAAD Pro. v8i by using response spectrum method. And calculate the lateral displacement, storey drift and base shear.

Authors and Affiliations

Bharat Sharan Shrivastava, Rashmi Singh

Keywords

Related Articles

Embedding Watermark in Wavelet Domain Using Chaotic Sequence

With the fast development of internet, Usage of various types of digital data like text, image, audio, video have been increased across the entire globe. Digital Media has several benefits like quality is higher, copyin...

Ultimate Strength Analysis of Concrete Filled Single and Double Skin Aluminium Tubular Columns with GFRP Laminates

This paper presents the results of rectangular aluminium columns and double skin rectangular columns of inner tube as PVC pipe wrapped with GFRP and the influence of the number of FRP layers are to be studied through ex...

Copy Cat: Effective Identification and Removal of Copy Cat Nodes in WSN

In this system, wireless sensor networks are more vulnerable to the node clone, and several distributed protocols have been proposed to detect this attack. So they require too strong assumptions that are to be practical...

Automobile Assistant Using Labview

Automobile assistant is using NI-myRIO based ultrasonic range sensor, safety feature which aids in monitoring the road for alerting the driver when an obstacle approaches, whenever the driver is distracted from driving....

AC-DC Converter with Flying Capacitor Using Three Phase Single Stage PFC & PWM

Today the wide usage of non linear loads like variable speed drives has made power factor improvement difficult due to the presence of harmonic currents. These harmonics cause overheating, and the amplification of these...

Download PDF file
  • EP ID EP24603
  • DOI -
  • Views 351
  • Downloads 11

How To Cite

Bharat Sharan Shrivastava, Rashmi Singh (2017). Analysis of Building with and without Shear Wall. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 5(6), -. https://europub.co.uk/articles/-A-24603