Analysis of high voltage shunt capacitor bank over-voltage breakdown detection

Journal Title: Future Energy - Year 2022, Vol 1, Issue 1

Abstract

The traditional over-voltage breakdown detection method ignores the suppression of the inrush current of over-voltage breakdown, resulting in low over-voltage signal detection accuracy and a large detection deviation. As a result, a method is proposed for detecting and analyzing the ageing over-voltage breakdown of high voltage shunt capacitor banks. The breakdown model of aged components of the container group is built to determine the breakdown time of the container's overvoltage. Based on this, the annual load of the capacitor bank's aged component material is evaluated, and data on over-voltage breakdown strength is collected. The Mallet algorithm is used to decompose and convert strength data into electrical signals. The high voltage shunt capacitor's over-voltage breakdown inrush current suppressor is built by combining the second-order under damping circuit and the voltage divider. Based on this, the parameters of HV shunt capacitor overvoltage breakdown are obtained, and the detection of HV shunt capacitor overvoltage breakdown of aged HV shunt capacitor banks is completed. The simulation results show that the proposed detection method's over-voltage breakdown output is in perfect agreement with the monitoring device's actual output and has ideal application performance.

Authors and Affiliations

Mohsen Rajabali Pour, Mohammad Azimian

Keywords

Related Articles

Impact Of Covid-19 on renewable energy sector and lessons learned: A case study on Malaysia

Coronavirus Disease 2019 (COVID-19) has been destructive in various sectors of Malaysia. In the renewable energy sector, Malaysia thrives in harvesting solar energy, biomass energy, and hydro energy, but despite years of...

Charge transport materials, bismuth and copper-based perovskite solar cells: A review

Improving perovskite solar cell (PSC) efficiencies would not have been possible without discovering and incorporating novel materials. More significant than materials usage is the compatibility of various material compon...

Greenhouse Gas Emission of Animal-Based and Plant-Based Products in Iran

These days, one of the major threats in the world is climate change. It is already proven by a large number of strong evidences that human activities are responsible for this sudden changes. It is expected that in future...

Solar power satellites: technical challenges and economic feasibility

World energy consumption is constantly rising; therefore, it is essential to investigate different possibilities to produce power in the medium and long term. The sun is a clean source of power that is virtually inexhaus...

Photodecomposition of water\ethanol mixtures for the production of hydrogen using as catalysts TiO2 fibers

The consumption of hydrogen as an automotive fuel has been growing since the 1980s. It can be used both as a gasoline blend and as a pure fuel. All human activities involve the use of energy. Some examples are: fuels for...

Download PDF file
  • EP ID EP709834
  • DOI 10.55670/fpll.fuen.1.1.11
  • Views 102
  • Downloads 0

How To Cite

Mohsen Rajabali Pour, Mohammad Azimian (2022). Analysis of high voltage shunt capacitor bank over-voltage breakdown detection. Future Energy, 1(1), -. https://europub.co.uk/articles/-A-709834