Abstract

Purpose. The study of parallel operation optimal modes of transformer equipment for a variety of operating conditions: same or different types of transformers, with or without reactive power flows. Methodology. Losses of energy in transformers make 30 % of all losses. Therefore the choice of the economically justified parallel operation of transformers is effective action to reduce losses. Typically, in the calculations of reactive power flows in the transformers are not taken into account. It is interesting to analyze the optimal operating conditions of transformers with and without reactive power flows. Results. Calculations for transformers in distribution networks showed that the inclusion of reactive power flows in transformers significant impact on the calculated optimum regimes of transformers.

Authors and Affiliations

I. V. Khomenko, S. K. Berezka

Keywords

Related Articles

THE THYRISTOR CONVERTER INFLUENCE ON THE PULSATIONS OF THE ELECTROMAGNETIC TORQUE OF THE INDUCTION MOTOR AT PARAMETRICAL CONTROL

Purpose. The purpose of the work is to identify the parameters influence of the electric motor, the power circuits elements of the converters, built on resistor-thyristor modules, the static torque and the moment of iner...

СONDITIONS INVESTIGATIONS OF INDUCTION OF THE "STEADY" PLASMA RING IN THE ELECTRODYNAMIC ACCELERATOR

The numerical investigation of conditions of the "steady" plasma ring induction in the electrodynamic accelerator was made. The influence of a ring resistance on transition of the ring to "steady" state was determined. T...

RESEARCH INTO ACTION OF SURFACE SOIL MOISTENING, DRYING OR FREEZING ON ELECTRICAL CHARACTERISTICS OF GROUNDING DEVICE

The analysis made has shown expediency of modernization rather than reconstruction of earth electrodes, after inspection of long operating substations grounding grids, via building a two-level structure. It will result i...

ON THE NEED TO INCREASE THE RELIABILITY OF LINEAR INSULATORS FOR DISTRIBUTION NETWORKS 10-20 KV

Introduction. In Ukraine high voltage overhead distribution lines (OL) of class 6 and 10 kV are the most extended. Their total length exceeds 280,000 km. More than 95 % of the lines are made on line supports from reinfor...

THE STABILITY MONITORING OF THE MANUFACTURING PROCESS OF ELECTRICAL INSULATING SYSTEMS OF TRACTION ELECTRIC MACHINES

Introduction. Electrical insulation systems make up about 0.03 % of the traction electric machines (TEM) mass, but they are of exceptional importance and affect the design capabilities and manufacturing techniques of ele...

Download PDF file
  • EP ID EP297051
  • DOI 10.20998/2074-272X.2016.6.12
  • Views 133
  • Downloads 0

How To Cite

I. V. Khomenko, S. K. Berezka (2016). ANALYSIS OF OPTIMUM OPERATING MODES OF POWER TRANSFORMERS UNDER OPERATING CONDITIONS. Електротехніка і Електромеханіка, 0(6), 70-73. https://europub.co.uk/articles/-A-297051