Analysis of oscillatory tanks of resonant inverner in power source mode

Abstract

The problems of power maintenance in variable load by means of voltage resonant inverters with various serial-parallel resonant tanks by the way of corresponding selection of its parameters is considered. A comparative analysis of three basic series-parallel oscillatory tanks of resonant inverter is accomplished. The inverter load is connected in parallel to the capacitance section of oscillatory tank and in series with inductance to half-bridge switching section. These resonant tanks are the next: 1) the tank with load connected in parallel to the first capacitor through the second capacitor;2) the tank with load connected in parallel to the first capacitor directly and through the second capacitor to the tank inductance; 3) the tank which topology corresponds to both above appointed tanks but differs from them by infinity capacitance of second capacitor. Analysis consists in establishing of analytical expressions which describe the connections between minimum and maximum power in variable load and corresponding values of oscillatory tank quality factor. On the basis of these expressions the equations for power relative deviations and parameters of resonant inverter are obtained. The dependency of power maintenance error vs. load resistance range is established. It is appointed that in case of equality of power for minimum and maximum loads, the maximum power deviation from given power in load range will reach its minimum value. It is showed that all considered tanks have practically equal possibilities in power maintenance but the first tank has highest efficiency and it is a best choice among these tanks. For all tanks the next assertion is established: the square of the quality factor which corresponds to the maximum load power level is equal to the multiplication of two quality factors which correspond to some less load power level. To ensure a small switching loss in resonant inverter, the parameters of oscillatory tanks are calculated taking into account the zero-voltage switching condition. Therefore the inverter resonant frequency which reaches its maximum value at maximum load resistance mustn’t exceeds the inverter switching frequency. The design sequence for calculation of each oscillatory tank parameters is proposed. This design sequence is based on a numerical solution of two equations set relative to tank parameters and parameter of inverter dc voltage. Calculated inductance, first and second capacitances, dc voltage of the inverter and its switching frequency ensure minimum value of maximum power deviation in given load resistance range. Calculated dependence of maximum deviation of relative power as a function of ratio of a maximum load resistance to its minimum value and the dependence of load power vs. load resistance verify the obtained results. It is shown that resonant inverter designed as open loop circuit is able to achieve the power deviations about of 6% of its nominal value for a double change in load resistance.

Authors and Affiliations

Anatoliy Lupenko

Keywords

Related Articles

Numerical and analytical solution of the problem on deformation of the circular cylinder using the Bessel functions

The elastic deformation of the plate in the form of a circular cylinder under the action of a smooth stamp contacting with the plate along the entire surface of the upper base is considered. The work deals with the findi...

Peculiarities of the local stresses field near the crack tip which goes out from the angular point of the broken interface

The homogeneous problem of the elasticity theory about the stress-strain state of piece-homogeneous body near the tip of the semi-infinity crack of arbitrary orientation under the plane strain is considered. The crack ti...

Destruction zone near the tip of interfacial crack at a prevailing tensile loading

Under the plane strain conditions at the prevailing tensile loading by Wiener-Hopf method the solutions of problems about the calculation of a small-scale destruction zone in the pre-fracture zone part, which is adjacent...

Bend of izotropic plate with two indentical co-axial open cracks at plastic zones meeting between them taking into account the contact of crack banks

A problem of biaxial bending under distributed on infinity moments of isotropic plate with the co-axial cracks of identical length is stated and solved. The vectors of the applied to the plate moments are perpendicular a...

Fracture pecularities of prestressed steel reinforcement under hydrogenation in the model working medium

Pecularities of fracture behaviour of progressively drawn pearlitic steels from the initial hot rolled bar (not cold drawn at all) to the final commercial product (prestressing steel wire) were investigated in air and un...

Download PDF file
  • EP ID EP571673
  • DOI -
  • Views 58
  • Downloads 0

How To Cite

Anatoliy Lupenko (2015). Analysis of oscillatory tanks of resonant inverner in power source mode. Вісник Тернопільського національного технічного університету, 78(2), 171-183. https://europub.co.uk/articles/-A-571673