ANALYSIS OF OVERVOLTAGES OCCURRING AT GROUNDING FAULTS IN A MEDIUM VOLTAGE NETWORK DEPENDING ON THE NEUTRAL TREATMENT

Journal Title: Journal of Sustainable Energy - Year 2017, Vol 8, Issue 3

Abstract

The importance of the system earthing in electrical station 110kV/MV is much known, ways to treat the neutral directly affecting the behavior of the system regarding the maximum level of earth-fault currents and of the overvoltages that can occur. In this paper the authors present considerations of the isolated and resistor treated neutral systems and make an analysis of the overvoltages that appear when the neutral is isolated comparing to the situation when it is treated by resistor. In the last part of the analysis the conclusions are presented.

Authors and Affiliations

MIRCEA P. M. , URSU D. , MARIN I. , BUZATU G. C.

Keywords

Related Articles

PROBABILISTIC APPROACH OF STABILIZED ELECTROMAGNETIC FIELD EFFECTS

Abstract - The effects of the omnipresence of the electromagnetic field are certain and recognized. Assessing as accurately as possible these effects, which characterize random phenomena require the use of statistical-pr...

ESTIMATION OF THE AMOUNT OF ELECTRIC ENERGY GENERATABLE PER YEAR USING RAIN ACCUMULATED WATER FROM ABOH AND AHIAZU MBAISE TO DRIVE A HYDRO TURBINE IN FUTO, NIGERIA

Flooding, which is now a yearly occurrence in most parts of the World, can be minimized if reservoirs are constructed at suitable locations to store rain accumulated water for the purpose of irrigation or electric po...

THERMAL POWER SYSTEMS DEVELOPMENT IN THE ROMANIAN CITIES ORADEA AND ZALÄ‚U BETWEEN 1918-2018

The energy evolution of Oradea and Zalau cities after 1918 took place in the difficult circumstances of Romania affected by two world wars and by a financial crisis in 1929-1933 interwar period. Thus, in the years follow...

THE MANAGEMENT AND ANALYSIS OF POWER QUALITY IN POWER DISTRIBUTION GRIDS BY USING PQVIEW SOFTWARE SYSTEM

Nowadays the power quality is considered one of the most important aspect regarding the performance of a power grid operator, concerning equally all the consumers categories, too. Since a low level of the power qual...

ACTUAL PROBLEMS FOR ROMANIAN RESEARCH IN THE ENERGY FIELD

The paper presents the actual situation and the problems the Romanian research in the energy field is confronted with in a period when budget financing has been drastically reduced as to the commitments and the forecasts...

Download PDF file
  • EP ID EP245098
  • DOI -
  • Views 108
  • Downloads 0

How To Cite

MIRCEA P. M. , URSU D. , MARIN I. , BUZATU G. C. (2017). ANALYSIS OF OVERVOLTAGES OCCURRING AT GROUNDING FAULTS IN A MEDIUM VOLTAGE NETWORK DEPENDING ON THE NEUTRAL TREATMENT. Journal of Sustainable Energy, 8(3), 121-127. https://europub.co.uk/articles/-A-245098