Analysis of Relative Biological Effectiveness of Proton Beams and Iso-effective Dose Profiles Using Geant4

Journal Title: Journal of Biomedical Physics and Engineering - Year 2017, Vol 7, Issue 2

Abstract

with proton beams in treatment planning systems (TPS) is of high significance. Given the significance of the issue and the studies conducted in the literature, this quantity is fixed and is taken as equal to 1.1. Objective: The main objective of this study was to assess RBE quantity of proton beams and their variations in different depths of the tumor. This dependency makes RBE values used in TPS no longer be fixed as they depend on the depth of the tumor and therefore this dependency causes some changes in the physical dose profile. Materials and Methods: The energy spectrum of protons was measured at various depths of the tumor using proton beam simulations and well as the complete simulation of a cell to a pair of DNA bases through Monte Carlo GEANT4. The resulting energy spectrum was used to estimate the number of double-strand breaks generated in cells. Finally, RBE values were calculated in terms of the penetration depth in the tumor. Results and Conclusion: The simulation results show that the RBE value not fixed terms of the depth of the tumor and it differs from the clinical value of 1.1 at the end of the dose profile and this will lead to a non-uniform absorbed dose profile. Therefore, to create a uniform impact dose area, deep-finishing systems need to be designed by taking into account deep RBE values.

Authors and Affiliations

M A Hosseini, S B Jia, M Ebrahimi-Loushab

Keywords

Related Articles

An Aptamer-based Biosensor for Troponin I Detection in Diagnosis of Myocardial Infarction

Background: Acute myocardial infarction (MI) accounts for one third of deaths. Cardiac troponin I (TnI) is a reliable biomarker of cardiac muscle tissue injury and is employed in the early diagnosis of MI. Objective: In...

Determining Changes in Electromyography Indices when Measuring Maximum Acceptable Weight of Lift in Iranian Male Students

Background: In spite of the increasing degree of automation in industry, manual material handling (MMH) is still performed in many occupational settings. The aim of the current study was to determine the maximum acceptab...

Reducing Radiation Doses in Female Breast and Lung during CT Examinations of Thorax: A new Technique in two Scanners

Background: Chest CT is a commonly used examination for the diagnosis of lung diseases, but a breast within the scanned field is nearly never the organ of interest. Objective: The purpose of this study is to compare the...

Alzheimer ’s Disease: Possible Mechanisms Behind Neurohormesis Induced by Exposure to Low Doses of Ionizing Radiation

In 2016, scientists reported that human exposure to low doses of ionizing radiation (CT scans of the brain) might relieve symptoms of both Alzheimer’s disease (AD) and Parkinson disease (PD). The findings were unbelievab...

Evaluation of Lung Density and Its Dosimetric Impact on Lung Cancer Radiotherapy: A Simulation Study

Background: The dosimetric parameters required in lung cancer radiation therapy are taken from a homogeneous water phantom; however, during treatment, the expected results are being affected because of its inhomogeneity....

Download PDF file
  • EP ID EP330343
  • DOI -
  • Views 126
  • Downloads 0

How To Cite

M A Hosseini, S B Jia, M Ebrahimi-Loushab (2017). Analysis of Relative Biological Effectiveness of Proton Beams and Iso-effective Dose Profiles Using Geant4. Journal of Biomedical Physics and Engineering, 7(2), 95-100. https://europub.co.uk/articles/-A-330343