Analysis of Retrofiton School Building With Shear Wall and Steel Bracing

Abstract

The earthquake on 30 September 2009with7,6 magnitude occurred in West Sumatera and it caused the damage to both physical public facilities and infrastructures. The education sectors suffered from structural damage to the school buildings. In order to establish of the new Indonesian Seismic Code, SNI03 1726 2012, it will affect to the performance of structures which was built before the establishment of the new seismic code, in which the building may not be adequate to with stand the working loads. In this study, the performance and structural strength of a two story RC school building SMAN3 Batusangkar designed using previous seismic code SNI03 1726 2002 and it was constructed before2009, was evaluated based on the new seismic code. The result of evaluation on the SMAN3 Batusangkar building shows that the building cannot resist the working loads applied to the structure, especially the earthquake loads, so the building structure needs to be retrofitted. Two retro fitted methods of the builiding were proposed in this study, they are using shear wall and steel bracing systems, which installed on the building frame with different locations. The addition of shear wall and steel bracing are very effective in strengthening the building structure, where the load bearing capacity of the structure increased significantly and the building is able to resist all working loads. Fauzan | Febrina. I. | Farizzia. S. | Yogii. R. | Zev A. J. "Analysis of Retrofiton School Building With Shear Wall and Steel Bracing" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Special Issue | International Conference on Advanced Engineering and Information Technology , November 2018, URL: https://www.ijtsrd.com/papers/ijtsrd19128.pdf Paper URL: https://www.ijtsrd.com/engineering/civil-engineering/19128/analysis-of-retrofiton-school-building-with-shear-wall-and-steel-bracing/fauzan

Authors and Affiliations

Keywords

Related Articles

Analysis on Glaucoma Detection

Glaucoma is a disease which leads to a permanent blindness to a person. Many techniques are available in medical industry to detect glaucoma. Some traditional techniques are HRT and COT. But both of them are cost effec...

Concentrations of Heavy Metals in Hair of Sudanese Exploration Mining Gold Workers as Indicators of Environmental Pollution

The aim of this study was to determine the concentration of Fe, Cu, Zn and Pb in scalp hair of Sudanese exploration mining gold workers in El Abedea town and healthy volunteers from Khartoum, using the XRF method. The ac...

Data Sharing with Sensitive Information Hiding in Data Storage using Cloud Computing

With cloud storage services, users can remotely store their data to the cloud and realize the data sharing with others. Remote data integrity auditing scheme is proposed to guarantee the integrity of the data stored in t...

Role of Uncertainty Reduction Strategies, Trust and Perceived Value in Social Shopping Intention

Social media such as Instagram, Facebook, and Line provide unparalleled platforms on which users can publicize their shopping experiences and related thoughts on specific e vendors within social networks. This has thus l...

LAN Based HF Radio Simulator An Approach to Develop an Early Prototype for Long Distance Radio Communication

Communication is considered one of the most decisive factors in winning a battle. That’s why every nation is very well focused to enhance its communication facilities. High Frequency HF radio communication system is a ma...

Download PDF file
  • EP ID EP592651
  • DOI 10.31142/ijtsrd19128
  • Views 50
  • Downloads 0

How To Cite

(2019). Analysis of Retrofiton School Building With Shear Wall and Steel Bracing. International Journal of Trend in Scientific Research and Development, 0(0), 156-164. https://europub.co.uk/articles/-A-592651