ANALYSIS OF SHORT CIRCUIT CONDITIONS IN HIGH POWER DEVICES

Abstract

Method of protection against failure or explosion hazard of semiconductor power devices, which can occur in high power converters, is discussed. This method base on a comparing of the permissible over current declared by manufactures, with the short-circuit current that can appear in case of failure. Different case of failure was analyzed and new criterion for protection of the semi-conductor power devices is proposed. Taking the declared current, and the calculated integral i2t as function of time, of the short circuit current, one is able to select circuit breaker operating time that should be applied in substation. This criterion assumed was verified with gut accuracy during experimental investigation in high current conditions. Tests were made at traction DC current unit of 3,3 kV and 1700 A.

Authors and Affiliations

Krzysztof ZYMMER, Ireneusz MAŚCIBRODZKI

Keywords

Related Articles

PRZEPŁYW POWIETRZA W PRZEMYSŁOWYM UKŁADZIE WENTYLACYJNYM

Urządzenia klimatyzacyjne są produkowane w bardzo dużych ilościach i należy dążyć do zmniejszenia poboru mocy ich siłowników. Zużycie energii przez siłowniki zależy od wymiarów przepustnic i w pewnym stopniu od nacisku p...

BADANIA STYKÓW UNIPOLARNYCH O OSIOWYM POLU MAGNETYCZNYM

Artykuł zawiera opis badań wykonanych w Zakładzie Wielkich Mocy Instytutu Elektrotechniki. Badano dwa rodzaje styków generujących osiowe pole magnetyczne stosowane w komorach wyłączników próżniowych. Badania łuku łączeni...

DESIGN TOOLS FOR THE DAYLIGHT IN BUILDINGS

The daylight in buildings is a complex phenomenon, primary because of its volatility. Currently the design of lighting needs of the various design tools. The study is an attempt to describe some of this tools with partic...

ANALIZA ROZKŁADU POLA ELEKTROMAGNETYCZNEGO POD LINIĄ ELEKTROENERGETYCZNĄ W RZECZYWISTYCH WARUNKACH TERENOWYCH WOLNA OD BŁĘDÓW WNOSZONYCH PRZEZ WAHANIA PRĄDÓW

W artykule przedstawiono nową metodę pomiaru rozkładu pola elektromagnetycznego pod liniami elektroenergetycznymi, która jest wolna od błędu wnoszonego przez wahania napięć, prądów i/lub odchyłki symetrii faz układu wiel...

AUXILIARY POWER CONVERTER WITH 3-LEVEL NPC STRUCTURE FOR RAILWAY APPLICATIONS – SIMULATION AND EXPERIMENTAL RESULTS

The paper presents AC/DC/AC converter with galvanic isolation of NPC (Neutral Point Clamped) multilevel structures. Selected simulation and experimental results of 3-level AC/DC/AC converter are presented.

Download PDF file
  • EP ID EP187725
  • DOI -
  • Views 48
  • Downloads 0

How To Cite

Krzysztof ZYMMER, Ireneusz MAŚCIBRODZKI (2012). ANALYSIS OF SHORT CIRCUIT CONDITIONS IN HIGH POWER DEVICES. Proceedings of Electrotechnical Institute Prace Instytutu Elektrotechniki, 59(258), 99-121. https://europub.co.uk/articles/-A-187725