Analysis of the Effect of carbon fiber utilization on Cobalt-60 Teletherapy to the depth dose and the surface dose

Abstract

The research about the effect of carbon fiber on cobalt-60 teletherapy type GWXJ80 to the depth dose when gamma rays passed the carbon fiber couch and its effect to the surface dose has been conducted. Depth dose has been measured using ionization detector 0.65cc Extradin A12 model with the buildup cup that is connected to the electrometer Max4000 (Standard Imaging). Depth dose data have been obtained from 5 cm, 6 cm, 7 cm and 9 cm of depth with angle variations of each depth are from 0o - 360o (10o angle interval ). The result of measurement has been processed using TRS398 protocol. The Surface dose measurement were performed using Gafchromic EBT2 film which was placed on the surface of slab phantom with and without carbon fiber. Irradiation field of this measurement were 6x6cm2, 8x8cm2, 10x10cm2, 12x12cm2, 14x14cm2, 16x16cm2 and 18x18cm2. The reading results of optic density using X-RITE densitometer were converted to dose refering the characteristic curve graph of Gafchromic EBT2 that had been prepared. Characteristic curve of the film have been made by giving 25cGy, 50cGy, 100cGy, 150cGy, 200cGy, 250cGy and 300cGy of dose to film strip in 2,5x3cm2 of field. The result of this research showed that in 5cm, 6cm, 7cm, 8cm and 9cm of the depth, can be obtained transmission factors 0.954, 0.952, 0.951, 0.950 and 0.948. A great transmission factor change occured at the gantry angle position at 100o to 120o. Carbon fiber application for the surface dose increased the relative dose from 10.9% into 37.4% (6x6cm2), 16.9% into 48.39% (8x8cm2), 23.0% into 63.3% (10x10cm2), 29.2% into 75.4% (12x12cm2), 33.3% into 80.1% (14x14cm2), 37% into 86.9% (16x16cm2) and 43.3% into 91.2% (18x18cm2).

Authors and Affiliations

Muhtarom M, Eko Hidayanto, Heri Sutanto

Keywords

Related Articles

Performance Analysis of OFDM system using LS, MMSE and Less Complex MMSE in terms of BER, SNR and MSE

In this research, Channel estimation has been accomplished for OFDM framework. In wireless communication, because of a nonappearance of channel estimation a decent execution of communication doesn't accomplish. Also, it...

A Survey on Machine Learning Algorithms

A large number of techniques has been developed so far to tell the diversity of machine learning. Machine learning is categorized into supervised, unsupervised and reinforcement learning .Every instance in given data-set...

AN EXPERIMENTAL INVESTIGATION ON THE STRENGTH PROPERTIES OF FLY ASH BASED BACTERIAL CONCRETE

The present investigation deals with the influence of Bacillus Subtilis bacteria on strength properties of fly ash concrete. In fly ash concrete, cement was partially replaced with 10%, 20% and 30% with fly ash by weight...

STUDY ON GEOPOLYMER CONCRETE USED FOR PAVING BLOCKS

Paver block is used in various applications like in street road and other construction places. Portland cement generates large amounts of carbon dioxide (CO2) which is responsible for global warming hence it is a greenho...

GRADIENT CALCULATION on the PLEURAL EFFUSION and NORMAL LUNGS IMAGE

A research of gradient calculation for pleural effusion and normal lungs images had been conducted. The gradient calculation was done by using gradient formula on the equation of line. The steps taken in this research we...

Download PDF file
  • EP ID EP177178
  • DOI -
  • Views 119
  • Downloads 0

How To Cite

Muhtarom M, Eko Hidayanto, Heri Sutanto (2017). Analysis of the Effect of carbon fiber utilization on Cobalt-60 Teletherapy to the depth dose and the surface dose. International Journal of Innovative Research in Advanced Engineering, 0(0), 65-68. https://europub.co.uk/articles/-A-177178