Analysis of the Effect of Phantom CT Scan Diameter Variations on Radiation Dose with IndoseCT
Journal Title: International Journal of Allied Medical Sciences and Clinical Research - Year 2019, Vol 7, Issue 1
Abstract
The dose received by a patient who performs a CT scan is influenced by several factors, namely slice thickness, pitch, position and size of the patient, range of scanning and type of scanning. The amount of radiation dose received from the scan also depends on phantom geometry, form and material. The method of calculating a patient's dose on a CT scan is known as the Computed Tomography Dose Index (CTDI). According to research that has already been carried out, it is explained that CTDI represents only the surface dose of the body. SSDE is then used to calculate the central dose of phantom and phantom edge. The purpose of this study was to determine the dosage size for variations in phantom diameter and SSDE values with the IndoseCT program for variations in phantom diameter. The measurement method in this study was carried out using a piranha detector and IndoseCT software. The results of the study found that there were differences in the values of CTDIc, CTDIw, and CTDIvol, each having a range of 0.93% to 147.96%, 26.65% to 62.48%, 11.51% to 41.46%. SSDE values for phantom size 8 cm, 16 cm, 24 cm, 32 cm and 40 cm respectively are as follows: 29 mGy, 23.09 mGy, 16.86 mGy, 12.35 mGy, 9.27 mGy. The conclusion of this study is that the greater the effective diameter of phantom the smaller the SSDE.
Authors and Affiliations
ntan Andriani
Studying the correlation between the history of fertility and menopause with bone density reduction and osteoporosis among postmenopausal women. A cross-sectional study
Background and Objective Bone density reduction and osteoporosis are the silent epidemic of present epoch. The world Health Organization (WHO) has announced it as forth enemy of human being after Cancer, Myocardial Infar...
The design of digital instrument connected to android based smartphone to measure radiation
Background Indonesian Government Regulation of 2007 on Safety and Health of Ionizing Radiation Utilization states that it is necessary to measure radiation exposure of X-ray machine for radiation protection for officers,...
A review on antidiabetic property of Costus Speciosus (Kemuka)
Medicinal plants have great importance in primary health care needs mankind and around 80% of world population relies on traditional medicinal system. India rich in herbal resources and Kemuka (Costus speciosus) is one o...
Heat of a moment takes life of innocent own kid- A rare case report
Murder, domestic violence, child abuse, rape and other crimes are daily headlines nowadays. These crimes have been integral part of our social structure since the inception of human existence and find place in all religi...
Comparison of Post Isometric Relaxation technique and Ischemic Compression technique on upper trapezius trigger points in high school girls with non specific neck pain: Randomized Clinical Trial
Background Neck pain contributes to be the second common musculoskeletal disorder in high school students. A significantly greater percentage of girls (21%) show symptoms during high school. Trigger points in upper fibre...