Analysis of the Effect of Phantom CT Scan Diameter Variations on Radiation Dose with IndoseCT

Abstract

The dose received by a patient who performs a CT scan is influenced by several factors, namely slice thickness, pitch, position and size of the patient, range of scanning and type of scanning. The amount of radiation dose received from the scan also depends on phantom geometry, form and material. The method of calculating a patient's dose on a CT scan is known as the Computed Tomography Dose Index (CTDI). According to research that has already been carried out, it is explained that CTDI represents only the surface dose of the body. SSDE is then used to calculate the central dose of phantom and phantom edge. The purpose of this study was to determine the dosage size for variations in phantom diameter and SSDE values with the IndoseCT program for variations in phantom diameter. The measurement method in this study was carried out using a piranha detector and IndoseCT software. The results of the study found that there were differences in the values of CTDIc, CTDIw, and CTDIvol, each having a range of 0.93% to 147.96%, 26.65% to 62.48%, 11.51% to 41.46%. SSDE values for phantom size 8 cm, 16 cm, 24 cm, 32 cm and 40 cm respectively are as follows: 29 mGy, 23.09 mGy, 16.86 mGy, 12.35 mGy, 9.27 mGy. The conclusion of this study is that the greater the effective diameter of phantom the smaller the SSDE.

Authors and Affiliations

ntan Andriani

Keywords

Related Articles

Evaluate the spectrum of surgical site infections in general surgery patients admitted at tertiary care centre of north india

Background Surgical site infections (SSIs) are infections present in any location along the surgical tract after a surgical procedure. SSIs involve postoperative infections occurring at any level (incisional or deep). Wi...

A review article for herbal drugs as anxiolytic activity

Anxiety is an emotional and physiological response to known or unknown causes that may range from a normal reaction to extreme dysfunction (indicative of an anxiety disorder), affect decision-making, adherence to treatme...

Immediate effect of vestibular exercise on blood pressure in healthy females

Background Both animal and human studies reported that stimulation of vestibular system alleviates stress and regulates blood pressure. Vestibular stimulation was reported to modulate the blood pressure and respiration t...

Silent but deadly: prevalence of breast problems among female students of secondary school, South Wollo, Ethiopia

Background The growing population in Ethiopia coupled with lifestyle changes will mean an increasing burden of breast problems which are warning signs of cancer. However, oncology services are wholly inadequate-no cancer...

A study to assess the information of communication on Knowledge regarding hazards of mobile Phone uses and prevention among Adolescents

Aim To evaluate the effectiveness of knowledge and attitude on hazards of mobile phone uses and prevention among nursing adolescents Participants and setting The objective of the study was to evaluate the effectiveness...

Download PDF file
  • EP ID EP535823
  • DOI -
  • Views 56
  • Downloads 0

How To Cite

ntan Andriani (2019). Analysis of the Effect of Phantom CT Scan Diameter Variations on Radiation Dose with IndoseCT. International Journal of Allied Medical Sciences and Clinical Research, 7(1), 21-27. https://europub.co.uk/articles/-A-535823