Analysis on the difference of circulating threshold of polymerase chain reaction in blood screening of external quality assessment

Journal Title: Chinese Journal of Blood Transfusion - Year 2022, Vol 35, Issue 9

Abstract

Objective To analyze the difference of circulating threshold (Ct) of polymerase chain reaction (PCR) in blood station laboratories during the external quality assessment, and to put forward suggestions for the quality improvement of participating laboratories. Methods From 2018 to 2021, the blood station laboratories participated in the external laboratory quality assessment of CITIC including blood screening items with nucleic acid testing method. The data of Roche diagnostic reagent group were used as the source, and the detected Ct values of three groups of quality control samples of HBV A subtype (400 IU/mL), HCV 1b subtype (400 IU/mL) and HIV B genotype (500 IU/mL) were used as the objects. The data were grouped according to quality control (sample) batches, reagent batches and different laboratories. Using the statistical method of variance analysis (assuming P<0.05 as significant), the detected Ct value of each group was analyzed. Results For the three items (HBV/HCV/HIV), the grouping data involving 42 batches of quality control (13/12/17), 28 batches of reagent (11/8/9) and 57 laboratories (19/19/19) were selected. The grouping analysis of quality assessment batches shows that there was no significant difference between HBV and HCV quality assessment batches, and there was no significant difference between other HIV batches except the two batches of HIV quality assessment samples released in 2021. The grouping analysis of each reagent batch showed that there was no significant difference between each reagent batch for HCV and HIV detection, while there was significant difference between two batches of HBV reagents. After excluding the data groups with significant differences in the quality control batch groups and the reagent batch groups, the detected Ct value of each laboratory group had extremely significant differences in the three items of HBV, HCV and HIV. Through pairing analysis, it was found that four laboratories had significant differences with most other laboratories in the three items, mainly manifested in the high mean value of Ct. Conclusion For the blood station laboratories with correct test results of quality assessment samples, there are differences in Ct values detected by PCR, which may be mainly caused by the detection ability of the participating laboratories.

Authors and Affiliations

Lidong LIU, Xiaofei WU, Yao JIA, Yuwen HUANG, Qin MO, Hong LIU, Rongna Ma, Zhong XU, Xun WANG

Keywords

Related Articles

A software for blood product information management: development and application

Objective To develop a mobile software application named " Component Assistant" and test for its performance in practical work, so as to address the difficulties and problems encountered during the management process of...

Analysis of risk factors in blood donors with confirmed positive syphilis

Objective To study the risk factors of blood donors confirmed to be positive for syphilis, so as to avoid highrisk groups, guide the recruitment of blood donors and improve blood safety. Methods From September 2021 to Au...

Risk factor analysis of plasma donation related vasovagal reaction

Objective To investigate the risk factors of vasovagal reactions(VVR) related to plasma donation, so as to put forward clinical suggestions for early identification and accurate intervention of high-risk groups to ensure...

Expert consensus on technical specifications for clinical blood use in medical institutions in Shenzhen

In medical institutions, clinical blood use involves multiple aspects. Clinicians not only need to possess good professional ethics to achieve rational use of blood, but also strictly adhere to transfusion-related laws,...

Cases report and diagnosis and treatment of passenger lymphocyte syndrome after liver and renal transplantation

Objective To summarize the clinical features, serological features, blood transfusion protocols and treatment of 3 cases of passenger lymphocyte syndrome(PLS) after ABO-incompatibility liver and renal transplantation in...

Download PDF file
  • EP ID EP738346
  • DOI 10.13303/j.cjbt.issn.1004-549x.2022.09.012
  • Views 41
  • Downloads 0

How To Cite

Lidong LIU, Xiaofei WU, Yao JIA, Yuwen HUANG, Qin MO, Hong LIU, Rongna Ma, Zhong XU, Xun WANG (2022). Analysis on the difference of circulating threshold of polymerase chain reaction in blood screening of external quality assessment. Chinese Journal of Blood Transfusion, 35(9), -. https://europub.co.uk/articles/-A-738346