ANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF DILTIAZEM HYDROCHLORIDE IN BULK AND PHARMACEUTICAL DOSAGE FORM BY RP- HPLC

Journal Title: International Journal of Drug Regulatory Affairs - Year 2014, Vol 2, Issue 2

Abstract

A simple, specific, precise and accurate Reverse Phase High Performance Liquid Chromatography (RP-HPLC) method was developed and validated for the estimation of Diltiazem Hydrochloride in bulk and pharmaceutical dosage form. The chromatographic determination was performed on isocratic high performance liquid chromatography system of Agilent model no.1220. The separation was conducted by using column of Zorbax [C8 (5μ, 4.6 mm×250)] with mobile phase consisting of buffer and Acetonitrile in the ratio of (60:40). The mobile phase was delivered at the flow rate of 1.0ml/min. The eluent was monitored at wavelength 240 nm and found a sharp and symmetrical peak with retention time of 4.66min. The method was validated for linearity, accuracy, precision, specificity, robustness. Recovery of Diltiazem Hydrochloride was found to be in the range of 98%-102%. The method was found to be linear over the concentration range 50-150 μg/ml with coefficient correlation r2 = 0.995. After developing method, validation parameters were carried out successfully and obtained results were complied with USP monograph.

Authors and Affiliations

Bhagyashree R. Patil, Bhusnure O. G. , Paul B. N. , Ghodke A. Y. , Suraj S. Mulaje

Keywords

Related Articles

COMPARISON OF GLOBAL REGULATORY GUIDELINES FOR AVAILABILITY OF DIFFERENT BIOWAIVER PROVISIONS AND APPLICATION REQUIREMENTS OF BIOPHARMACEUTICS CLASSIFICATION SYSTEM (BCS) BASED BIOWAIVER.

To waive a complete and systemic Bioequivalence (BE) study, Biowaiver or Request for a Biowaiver is a fast track approach to boost the drug development process. Over the past three-four years the Biowaiver market shows g...

OCULAR DRUG DELIVERY: RECENT UPDATES

Ophthalmic route is one of the most promising delivery systems for the treatment of eye ailments. Delivery of medicaments to anterior segment of the eye is an easy task. However with the rising number of posterior segmen...

Pre-filled syringes in developed and developing region: An insight into Regulatory considerations

A Pre-filled syringe is a disposable syringe that is supplied already loaded with the substance to be injected. It is a unit dose of parenteral medication to which a needle has been fixed by a producer. They are small wh...

PHARMACOVIGILANCE IN CLINICAL RESEARCH: PAST, PRESENT AND FUTURE

The growing clinical research after the product patents rights for the pharmaceutical industries as per the trade related aspects of intellectual property rights agreement and adverse drug reaction monitoring of the mark...

REVIEW ON SPONSOR / APPLICANT MEETINGS WITH FDA: HIGHLIGHTS OF NEW GUIDANCE OVER EXISTING

The United States Department of Health and Human Services has a federal agency called the Food and Drug Administration (FDA or USFDA). A pre-planned assembling of two or more people who have been together for the purpose...

Download PDF file
  • EP ID EP349806
  • DOI 10.22270/ijdra.v2i2.133
  • Views 96
  • Downloads 0

How To Cite

Bhagyashree R. Patil, Bhusnure O. G. , Paul B. N. , Ghodke A. Y. , Suraj S. Mulaje (2014). ANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF DILTIAZEM HYDROCHLORIDE IN BULK AND PHARMACEUTICAL DOSAGE FORM BY RP- HPLC. International Journal of Drug Regulatory Affairs, 2(2), 78-84. https://europub.co.uk/articles/-A-349806