Analyzing an error in the synchronization of hydraulic motor speed under transient operating conditions

Abstract

<p>A hydraulic drive with two hydraulic cylinders was considered in which the rod movement speeds are synchronized by a divider of the working fluid flow. Based on the developed mathematical model, operation of synchronized hydraulic cylinders in transient operating conditions with a sudden change of load on one of the hydraulic cylinders was calculated. Speeds of movement of the hydraulic cylinder rods and pressures in the inter-throttle chambers of the flow divider were determined. It was established that there were variations of pressure in the inter-chamber chambers of the flow divider in the transient conditions of operation of the drive caused by a sudden change of load on the hydraulic cylinders and, as a result, an error of synchronization of speed of movement of the cylinders rods appeared at the initial stage. Relative pressure differential in the inter-throttle chambers reached 1 and the relative difference of speeds of movement reached 0.43. To improve accuracy of synchronization of hydraulic motor movement, a flow divider was proposed with an additional feedback in the pressure differential in the inter-throttle chambers of the divider. The additional feedback was realized through the use of a double-slotted throttling distributor of the spool-valve type. Proceeding from the conditions of a minimum synchronization error, the necessary dependence of change of area of the working slot of the controlled throttles was determined and recommendations on profiling the working slots of the spool throttle were given.</p><p>It was established by calculation and confirmed experimentally that the use of controlled throttles reduces the error of synchronization of speed of movement of the cylinder rods to 0.27 and the pressure differential in the inter-throttle chambers of the flow divider to 0.53.</p><p>Harmonics of higher order occurred in a transient process for speed and pressure. They were caused by movement of the spool valve of the double-slot distributor.</p><p>Presence of harmonics of higher order in variations of pressure and velocity did not significantly affect operation of hydraulic motors since amplitude of these variations was negligible.</p><p>Reduction of the speed synchronization error is due to simultaneous change of area of the throttle which stabilizes pressure differential and the area of the controlled throttle.</p>

Authors and Affiliations

Oleksii Havrylenko, Serhii Kulinich

Keywords

Related Articles

CONSTRUCTION OF AN ALGORITHM FOR BUILDING REGIONS OF QUESTIONABLE DECISIONS FOR DEVICES CONTAINING GASES IN A LINEAR MULTIDIMENSIONAL SPACE OF HAZARDOUS FACTORS

The issue of danger emanating from industrial devices with combustible gases has been considered in the linear multidimensional continuous space of dangerous factors. Dangerous factors are categorized into factors associ...

Analysis of amplitude-phase functions of the drill string as a component of automation systemAnalysis of amplitude-phase functions of the drill string as a component of automation system

<p class="1">We determined amplitude-phase frequency functions of the drill string for translational motion while drilling with immersed engines. It was established that amplitude-phase characteristic of the drill string...

Experimental study of temperature mode of a fire in a cable tunnel

<p>We established, based on the conducted research into a change in temperature in the cable tunnel during fire, that in the combustion zone the temperature grows faster in comparison with the standard temperature mode o...

Surface hardening and finishing of metallic products by hybrid laser­ultrasonic treatment

<p>Theoretical and experimental study of the possibilities of using laser heat treatment (LHT) combined with ultrasonic impact treatment (UIT) for surface hardening and finishing of metallic products was carried out. The...

Simulation of structure formation in the Fe–C–Cr–Ni–Si surfacing materials

<p>The paper investigates the formation of equilibrium phase state in the surfacing materials 300Cr25Ni3Si3 and 500Cr40Ni40Si2BZr, obtained by electric arc surfacing that employs powder tapes PL AN-101 and PL AN-111. Thi...

Download PDF file
  • EP ID EP666902
  • DOI 10.15587/1729-4061.2019.175033
  • Views 68
  • Downloads 0

How To Cite

Oleksii Havrylenko, Serhii Kulinich (2019). Analyzing an error in the synchronization of hydraulic motor speed under transient operating conditions. Восточно-Европейский журнал передовых технологий, 4(7), 30-37. https://europub.co.uk/articles/-A-666902