Antibiotic-laden Arthroplasty with a Novel Design of Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases

Journal Title: Malaysian Orthopaedic Journal - Year 2017, Vol 11, Issue 2

Abstract

Infection of the hip after implant fixation is an uncommon yet devastating complication that results in poor long-term outcome. The gold standard treatment for chronic infection after hip arthroplasty is a two-stage protocol: eradication of infection, follow by re-implantation arthroplasty. The use of interim antibiotic-laden cement spacer has become a popular procedure to maintain hip joint function and provide antibiotic elution simultaneously before re-implantation. However, antibiotic cement spacer is mechanically weak and breaks if overloaded. Therefore, we designed a cement mould with metallic endoskeleton with the aim of creating a stronger, inexpensive, antibiotic-impregnated spacer resembling a unipolar arthroplasty. We report two cases of severe hip joint infection after implant fixation (bipolar hemiarthroplasty, screw fixation neck of femur). Both patients had undergone first stage surgery of debridement and articulating antibiotic cement insertion using our design. Although the second stage surgery was planned for these patients, both patients delayed the operation in view of good functional status after a year walking with the antibiotic cement spacer. These cases showed that the mechanical property of the new antibiotic cement spacer was promising but further mechanical studies upon this new endoskeleton design are required.

Authors and Affiliations

William CCH, Simmrat S, Suhaeb AM

Keywords

Related Articles

Does the Quality of Life in Operated Patients with Adolescent Idiopathic Scoliosis correspond with the Radiographic Parameters?

Objectives: Traditionally, scoliosis surgery is aimed at attaining a fused, balanced and painless spine. With improvement in surgical and instrumentation techniques, spine surgeons strive to achieve higher degree of Cobb...

Adolescent Volar Barton Fracture with Open Physis treated with Volar Plating using Buttressing Principle

Objective: The objective of the study was to assess the outcome of Salter- Harris type III distal radius fracture fixed using the principle of buttressing and avoiding screw insertion through the physis. Materials and M...

Extracellular Vesicles in the Synovial Joint: Is there a Role in the Pathophysiology of Osteoarthritis?

The role of extracellular vesicles (EV) in osteoarthritis has become the focus of much research. These vesicles were isolated from several cell types found in synovial joint including chondrocytes and synovium. As articu...

Determining if Positive Predictive Value using Laboratory Risk Indicator for Necrotising Fasciitis is Applicable in Malaysian Patients with Necrotising Fasciitis

Introduction: Necrotising fasciitis (NF) is a rapidly progressive infection of the subcutaneous tissue and fascia which spreads rapidly. The scoring system of Laboratory Risk Indicator for Necrotising Fasciitis (LRINEC)...

Issues Related to Authorship

With advancements in telecommunication, information can be disseminated more rapidly and effectively. Many journals especially those that allow online access are providing additional channels for articles or reports to b...

Download PDF file
  • EP ID EP310580
  • DOI 10.5704/MOJ.1707.015
  • Views 125
  • Downloads 0

How To Cite

William CCH, Simmrat S, Suhaeb AM (2017). Antibiotic-laden Arthroplasty with a Novel Design of Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases. Malaysian Orthopaedic Journal, 11(2), 78-81. https://europub.co.uk/articles/-A-310580