Application andevaluation of random quality control sampling in donor blood detetion by ELISA

Journal Title: Chinese Journal of Blood Transfusion - Year 2023, Vol 36, Issue 9

Abstract

Objective To evaluate the effectiveness of random quality control sampling in blood sample detetion by ELISA. Methods Blood samples of 5 mL specification of blood donors from our blood station from May to July 2022 were selected for routine operation on a fully automated sampler. J standard substances(3 mL specification) as daily samples were added to A1 well, H12 well and random wells of HBsAg, anti-HCV, anti-HIV, and -TP, and then placed in a fully automated enzyme immunoassay analyzer for testing. With random well quality control as the internal quality control judgment standard, 20 consecutive tests were conducted and were divided into A1 (well) group, H12 (well) group and random (well) group according to different well positions. Quality control maps were drawn using Levey-Jennings quality control chart with random group as the framework, and were compared with the quality control map of A1 well and H12 well results in the same day. Results The mean quality control levels of infectious indicators of blood transfusion in blood donors by ELISA were: HBsAg 3.87±0.28, anti-HCV 3.79±0.38, anti-HIV 3.64±0.30 and anti-TP 4.53±0.51. Comparison of HBsAg, anti-HCV, anti-HIV and anti-TP, between random group, A1 group and H12 group were HBsAg 3.87± 0.28 vs 4.09±0.30 vs 3.64±0.26, anti-HCV 3.78±0.37 vs 3.96±0.38 vs 3.63±0.38, anti-HIV 3.63±0.31 vs 3.82±0.32 vs 3.48±0.28 and anti-TP 4.51±0.51 vs 4.71±0.52 vs 4.36±0.51, The S/CO value of each indicator were H12 group<random group<Al group (P<0.05), and the mean quality control levels of random group were similar to each detection indicator (P>0.05) . Using random group as the quality control framework standard, 5 points in group A1 fell outside of +2s, and 1 point in group H12 fell outside of -2s, resulting in a total of 6 alarms. With the quality control substance placed in A1 well of the ELISA plate, the judgment of detection results of the entire ELISA plate could be inevitably affected, especially the last row of low concentration virus marker samples on the ELISA plate. Conclusion The application of random quality control sampling method in donor blood by ELISA is scientific and reasonable, which can reduce the systematic error caused by artificial setting of ELISA plate fixed well positions and can also discover edge effects that affect the detection results.

Authors and Affiliations

Youjiang FENG, Kaiming YU

Keywords

Related Articles

Preparation of a novel double polymerized of red blood cell substitute and preliminary observation of its curative effect

Objective To study the red blood cell substitute preparation method of glutaraldehyde(GDA) and Bis(3, 5-dibromosalicyl) fumarate(DBBF) double polymerized, and also observe its curative effect. Methods The affecting facto...

Expert consensus on technical specifications for ABO blood group detection in clinical laboratories in Shenzhen

To meet the time-sensitive requirements of transfusion therapy, clinical laboratory testing for ABO blood typing must be conducted swiftly and accurately. To achieve this, laboratory technicians need to master the underl...

Performance verification of domestic nucleic acid testing system in blood stations based on T/CSBT

Objective To explore the performance verification of the Shengxiang automatic NAT system for HBV DNA, HCV RNA and HIV RNA-1 using PCR-fluorescence in the laboratories of blood stations, in order to meet the requirements...

Serological and genetic analysis of a Bel subtype caused by a novel 29insG mutation: a case report

Objective To investigate the serological characteristics and molecular mechanism of a case of Bel subtype. Methods Serological method was used to analyze the ABO blood group of the patient, absorption and elution test wa...

Analysis of platelet apheresis transfusion trends in Suzhou from 2017-2022

[Objective] To investigate the clinical characteristics of patients who underwent multiple platelet transfusions (≥2 times) in Suzhou over the past 5 years (2017-2022), as to provide new insights for patients requiring l...

Download PDF file
  • EP ID EP738644
  • DOI 10.13303/j.cjbt.issn.1004-549x.2023.09.017
  • Views 48
  • Downloads 0

How To Cite

Youjiang FENG, Kaiming YU (2023). Application andevaluation of random quality control sampling in donor blood detetion by ELISA. Chinese Journal of Blood Transfusion, 36(9), -. https://europub.co.uk/articles/-A-738644