Application of antibiotics in the sterilization of homogeneic heart valves
Journal Title: Advances in Hygiene and Experimental Medicine - Year 2017, Vol 71, Issue
Abstract
A significant deficit in the availability of human tissues has not resulted in less general interest in homogeneous heart valves. The application of homografts still remains the optimal solution in the surgical treatment of congenital and acquired defects. Obtaining the optimal properties of these valves is followed by processing, including sterilization. This method provides sterility with rewarding cell viability and maintenance of the tissues’ native features. The prepared material possesses appropriate properties at the level of structure and surface, which results in correct functioning in vivo. During the past several decades, sterilization conditions and the compositions of antibiotic mixtures have changed significantly. In this period, significant progress in the development of this method was achieved; however, in the last few years, various flaws in antibiotic sterilization of homografts have been revealed. The release of the antibiotic during microbiological tests of tissue evaluated for implantation or the possibility of side effects as a result of antibiotic release after implantation remain the most important issues here. In this work we characterized the main antibiotic mixtures that are currently in use.
Authors and Affiliations
Artur Turek, Justyna Wilińska, Aleksandra Borecka, Lucyna Pawlus-Łachecka
Czy preparaty stosowane w leczeniu cukrzycy typu 2 mogą indukować ostre zapalenie trzustki?
Rosnąca liczba osób chorujących na cukrzycę typu 2, wprowadzanie do praktyki klinicznej kolejnych nowych leków hipoglikemizujących oraz dążenie do uzyskania jak najlepszej kontroli glikemii przy zastosowaniu politerapii...
Wpływ 28-O-propynoilobetuliny na proliferację i apoptozę ludzkich komórek czerniaka melanotycznego i amelanotycznego
Comparison of the usefulness of selected formulas for GFR estimation in patients with diagnosed chronic kidney disease
Introduction: The diagnosis and classification of chronic kidney disease (CKD) are based on the glomerular filtration rate value. The simplest way to evaluate glomerular filtration rate is to estimate it based on serum c...
Application of microcomputed tomography for quantitative analysis of dental root canal obturations
Introduction: The aim of the study was to apply microcomputed tomography to quantitative evaluation of voids and to test any specific location of voids in tooth’s root canal obturations. Materials and Methods: Twenty roo...
Amylina w badaniach eksperymentalnych. Fibrylotwórczy polipeptydowy hormon trzustki
W przebiegu cukrzycy typu 2 (diabetes mellitus type 2 DM2, non-insulin dependent diabetes mellitus, NIDDM) oraz w rozwoju guza insulinowego trzustki, obserwuje się w obrębie wysp Langerhansa, patologiczne depozyty zwane...