Application of Direct Optimization Method by Zooms to Improve the Performances of AC Electromagnet
Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2018, Vol 42, Issue 0
Abstract
The paper seeks to improve the force developed by an AC electromagnet at maximum air-gap, using the direct optimization method by zooms, based on numerical experiments performed by finite element method (FEM) in ANSYS software. In a previous work, a 5.68% improvement in the static force characteristic of the same device was achieved and particularly, a 12.63% improvement in the force at maximum air-gap, taking into account three very influential geometrical parameters: the rate of bottom core thickness, rate of ring width and the rate of lateral core thickness. The optimization problem was subject to constraints of maintaining the overall dimensions of the device. The research continues in this paper with the search for the optimal geometrical configuration to provide a maximum developed force in the "open" position, replacing the parameter rate of ring width, having the least influence, with the parameter rate of winding thickness and adding the constraint of maintaining the cross-section of the winding. A device screening ensures that all the new three parameters are worth considering with a confidence level greater than 99%. The solution of the optimization problem brings an improvement of 25.67% of the acting force and of 7.09% of the static characteristic. The magnetic force was determined based on the principle of virtual work, available in ANSYS software.
Authors and Affiliations
Alin-Iulian Dolan
Static Force Characteristic and Thermal Field for a Plunger-Type AC Electromagnet
In this paper we propose an approach for the de-termination of static force characteristic of a plunger-type AC electromagnet using 2D numerical model developed in QuickField software and the determination of the thermal...
Study of the Reactive Power Side Effects for Tariff and Compensation Purpose at the Transmission Networks’Users
The reactive power flows affect voltages, losses and transmission capacities. Thus MVAR flows are a matter of increasing concern for the grid operators and the Romanian Regulatory Authority for Energy has established the...
Design of Separately Windings Control System of Series/Compound DC Traction Motors
This paper focuses on the problem of the control system of Series/Compound DC motor in both areas of speed adjustment. Traditional field weakening is achieved by means of resistances and contactors wich inserting and...
ELASTIC EQUIVALENT SPRING FOR THE ELECTROMECHANICAL CIRCUIT BREAKERS DRIVEN BY ELECTROMAGNETS
The aim of the present paper is to analyze the transient phase of electromagnetic actuators mechanisms of the electrical switching device by two different analytical methods, in order to simplify the determination of the...
Shielding Effectiveness Measurement Using a DTEM Cell
This paper presents a shielding effectiveness evaluation for some metallic threads materials. The tests were performed using a non-standardized method in a dual transversal electromagnetic cell (DTEM). The materials’ shi...