Application of improved comparability verification method in performance verification of instruments and equipment
Journal Title: Chinese Journal of Blood Transfusion - Year 2022, Vol 35, Issue 10
Abstract
Objective To explore the viability of improved comparability verification method for the performance verification of automatic biochemical analyzer in blood centers. Methods According to the relevant requirements of User Verification of Performance for Precision and Trueness; Approved Guideline-Second Edition (EP15-A2) and Guideline for Comparability Verification of Quantitative Results with One Health Care System(WS/T 407-2012), the performance of the newly purchased Beckman Coulter AU480 automatic biochemical analyzer was confirmed by means of comparability verification, and compared with the current Olympus AU400 automatic biochemical analyzer. Results The detection results given by Beckman AU480 biochemical analyzer on 5 samples for ALT detection performance test were significantly correlated with the target value (R2=0.998), and the trueness verification results met the requirements.The CV of medium and high ALT levels was 2.36% and 1.20%, respectively, within the acceptable standard range(<5%), and the precision verification results meet the requirement.The comparison deviation of two devices for medium and high ALT levels was 0.47% and 1.62%, respectively, within the acceptable standard range (<5%). The detection results of ALT from 40 blood donors given by two devices were significantly correlated (R2=0.956), and the precision verification results met the requirements.In the validation of linear evaluation, there was a good linear relationship between the expected and measured results (r=0.997)among samples with 6 levels of concentrations. Conclusion The comparability verification method is suitable for the performance verification of automatic biochemical analyzer in blood centers.
Authors and Affiliations
Jiang QIAN, Zhongmei LIU, Xiaomin ZHOU
Molecular biological analysis of RhD variant blood donors in Zhengzhou
Objective To investigate the serological characteristics and gene mutation mechanism of RhD variant blood donors in Zhengzhou. Methods From January 2023 to December 2023, 1 619 RhD-negative blood donors sent to our labor...
Bibliometrics and visual analysis of platelet rich plasma based on strategic coordinate diagram and co-word analysis
Objective To explore the research status, hot spots and trends of platelet rich plasma (PRP). Methods With "platelet rich plasma (PRP)" and its Chinese equivalent as the subject words, the PRP related articles during Jan...
Molecular mechanism of ABO bood group variation
Objective To study the relationship between ABO subtype, para-Bombay blood group and genotype, so as to explore the possible molecular mechanism of these two blood groups, and provide accurate genetic detection targets a...
Genetic analysis of a weak D type61 sample from a blood donor, Jiangyin
Objective To genetically analyze the Del sample from a blood donor in Jiangyin and make clear the molecular basis of the serological phenotype. Methods The EDTA anticoagulant blood were collected: buffy coat were used fo...
Study on transfusion-related acute lung injury caused by HLA-Ⅱ antibody
Objective To explore the risk factors of transfusion-related acute lung injury (TRALI). Methods The clinical symptoms, signs, imaging examinations, and laboratory test results of two patients with TRALI after blood trans...