Application of quality monitoring indicators of blood testing in blood banks of Shandong province

Journal Title: Chinese Journal of Blood Transfusion - Year 2024, Vol 37, Issue 3

Abstract

Objective To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. Methods A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. Results The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. Conclusion The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.

Authors and Affiliations

Xuemei LI, Weiwei ZHAI, Zhongsi YANG, Shuhong ZHAO, Yuqing WU, Qun LIU, Zhe SONG, Zhiquan RONG, Shuli SUN, Xiaojuan FAN, Wei ZHANG, Jinyu HAN, Lin ZHU, Xianwu AN, Hui ZHANG, Junxia REN, Xuejing LI, Chenxi YANG, Bo ZHOU, Haiyan HUANG, Guangcai LIU, Ping CHEN, Hui YE, Mingming QIAO, Hua SHEN, Dunzhu GONGJUE, Yunlong ZHUANG

Keywords

Related Articles

Progress in the construction of immortalized cells

Objective In the process of proliferation and division, normal human cells reach the mortality stage M1 and mortality stage M2, which makes the cells stop division and apoptosis. This irreversible physiological process i...

Evaluation and improvement of blood station quality management system: based on external audit

Objective To identify the main unqualified items in the external audit of blood station quality management system (referred to as external audit), in order to take necessary measures to continuously improve the quality s...

Chinese expert consensus on standardized application of automation technology for transfusion compatibility testing

Given the increasingly widespread application of automation technology in transfusion compatibility testing, in order to reduce the systemic and hidden risks of automated testing equipment, to provide guidance for the st...

Correlation between heart rate variability and psychological evaluation before blood donation

Objective To investigate the correlation between heart rate variability (HRV) and the degree of nervousness before blood donation. Methods The psychological state of 253 blood donors before blood donation was assessed by...

Application evaluation of detection system based on microfluidic technology in initial screening of blood donors

Objective To evaluate the screening efficacy and practical value of the portable microfluidic biochemical analyzer in the detection of blood donors before blood donation. Methods Blood donor samples, clinical blood sampl...

Download PDF file
  • EP ID EP738775
  • DOI 10.13303/j.cjbt.issn.1004­549x.2024.03.002
  • Views 37
  • Downloads 0

How To Cite

Xuemei LI, Weiwei ZHAI, Zhongsi YANG, Shuhong ZHAO, Yuqing WU, Qun LIU, Zhe SONG, Zhiquan RONG, Shuli SUN, Xiaojuan FAN, Wei ZHANG, Jinyu HAN, Lin ZHU, Xianwu AN, Hui ZHANG, Junxia REN, Xuejing LI, Chenxi YANG, Bo ZHOU, Haiyan HUANG, Guangcai LIU, Ping CHEN, Hui YE, Mingming QIAO, Hua SHEN, Dunzhu GONGJUE, Yunlong ZHUANG (2024). Application of quality monitoring indicators of blood testing in blood banks of Shandong province. Chinese Journal of Blood Transfusion, 37(3), -. https://europub.co.uk/articles/-A-738775