APPLICATION OF THE REBA METHOD TO OSH SYSTEMS TO INCREASE WORK PRODUCTIVITY (A CASE STUDY AT PT. EKSONINDO MPI, BANDUNG, INDONESIA)
Journal Title: International Journal of Civil Engineering and Technology - Year 2019, Vol 10, Issue 3
Abstract
PT. Eksonindo MPI is a company that manufactures various kinds of bags that are marketed with Export, Eiger and Bodypack trademarks. At present, operators who carry out their work often complain that certain parts of their body hurt. This pain is caused by the presence of a poor working system. Improving the work system can be accomplished by analyzing the body posture of nine specific work activities. Analysis of the worker’s posture employs the REBA method. The results of the REBA analysis indicate that all nine activities carry moderate and high risks. Proposed improvements have been made by designing table and chair sizes using the anthropometric data of the Indonesian workers involved. The proposed improvements made at a later stage were simulated and recalculated using the REBA score. The simulation results of proposed improvements show a significant improvement so that it will be convenient as a safety fund or investment for workers.
Authors and Affiliations
PAULUS SUKAPTO, FRANZESKA CYNTHIA and SEBASTIAN STANDIKLAUS
A COMPREHENSIVE REVIEW OF FAILURE AND COLLAPSE OF BUILDINGS/STRUCTURES
In this paper, the studies of research works related to Failure and Collapse of Buildings/Structures are reviewed. A model which researchers can use for selecting the journal for publishing their research work is propo...
A STUDY ON THE STRENGTH PARAMETERS OF CONCRETE WITH BAGASSE ASH AS A PARTIAL REPLACEMENT OF CEMENT AND MARBLE WASTE AS PARTIAL REPLACEMENT OF COARSE AGGREGATE
This research paper presents the experimental study to find out strength parameter of sugarcane with partial replacement of cement and marble waste as partially and fully replacement with coarse aggregates. Addition of...
MINIMIZING OF SCOUR DOWNSTREAM THE OUTLETS OF THE BOX CULVERT
Local scour downstream the box culverts outlet may cause to a complete failure of the culvert structure. New research is employed to reduce the max scour depth downstream the outlet of the box culvert under a different...
STRENGTH STUDIES ON BIO CEMENT CONCRETE
This study investigates the effect of deploying Bio cement on mechanical properties of hardened concrete of Grade M25. Percolation of crack can lead to leakage problems causing concrete matrix deterioration or corrosio...
STUDYING THE EFFECT OF ADDING ANTIMONY (SB) TO THE LEAD BASE ALLOYS ON CORROSION IN ACIDIC MEDIUMS
Due to the toxicity and harmful environmental effect of (Pb) because the potential electrode values tendency to losses ions and oxidization, Antimony adding impact in the range of (2-15) wt. % to lead on the corrosion...