ارائه مدل برنامه‌ريزي خطي فازي جهت ارتقاء بهره‌وري انرژي الکتريکي در تأسيسات تأمين آب شرب (مطالعه موردي: طرح آبرساني سيستان)

Journal Title: آب و فاضلاب - Year 2018, Vol 29, Issue 1

Abstract

A Fuzzy Linear Programming Model for Improving Productivity of Electrical Energy in Potable Water Supply Facilities (Case study: Sistan Water Supply Project) One of the most important operational issues in urban drinking water production and distribution systems is to assign a plan for running hours of water pumps. The cost of consuming electricity in these pumps allocates most of water and wastewater companies operational costs to itself which is dependent to their running hours. In this paper, meanwhile having a field study in rural water and wastewater company of Sistan, the constraints for specifying electric pumps operational time in water supplying resources such as restrictions in fulfilling demand, supply potable water with suitable quality and uselessness of electric pumps have been identified. Due to uncertainty and fuzziness of the constraints, a linear programming model with fuzzy constraints for determining electric pumps running hours per day is submitted with the objective to minimize electricity consumption and cost. After collecting and using required data for model, it proved that using the proposed model could reduce the costs of electrical energy and increase productivity up to 23 percent per month. The proposed mathematical fuzzy programming is able to specify electric pumps scheduling plan for water supply with the aim to reduce the costs of consuming energy. .

Authors and Affiliations

Vahid Baradaran, Abdolvesal Chari

Keywords

Related Articles

ارزيابي عملکرد مالي صنعت آب و فاضلاب شهري بر اساس مدل BSC

Using the BSC Model to Evaluate the Financial Performance of the Urban Water and Wastewater Industry Among the different models so far proposed for the guiding and evaluation of organizational performance, the balanced s...

فعال‌سازي گرافن اکسايد باHCI به‌منظور حذف نيترات از محيط‌هاي آبي (بررسي سينتيک و مکانيسم واکنش‌ها)

Activation of Graphene Oxide with Hydrochloric Acid for Nitrate Removal from Aqueous Solutions A. Alighardashi1, Z. Kashitarash-Esfahani2, A. Afkhami3 1. Assist. Prof. of Environmental Engineering, Department of Civil...

جداسازي و پيش‌تغليظ مقادير کم نيکل از نمونه‌هاي آبي با استفاده از نانولوله‌هاي کربني مغناطيسي

Separation and Preconcentration of Trace Amounts of Nickel from Aqueous Samples In this paper, a new method for preconcentration and measurement of trace amounts of nickel in aqueous samples by magnetic solid phase extr...

Hybrid Nano-filtration and Micro-filtration Pilot Processes for the Removal of Chromium from Water ساخت پايلوت هيبريد فرايندهاي نانوفيلتراسيون و ميکروفيلتراسيون به‌منظور حذف کروم شش ظرفيتي از آب

Abstract Heavy metal hexavalent chromium is known as a highly toxic compound and based on World Health Organization standards in concentrations greater than 50 micrograms per liter would lead to diseases such as allergi...

Download PDF file
  • EP ID EP332979
  • DOI 10.22093/wwj.2017.7157.1504
  • Views 108
  • Downloads 0

How To Cite

Vahid Baradaran, Abdolvesal Chari (2018). ارائه مدل برنامه‌ريزي خطي فازي جهت ارتقاء بهره‌وري انرژي الکتريکي در تأسيسات تأمين آب شرب (مطالعه موردي: طرح آبرساني سيستان). آب و فاضلاب, 29(1), 27-36. https://europub.co.uk/articles/-A-332979