Are Cutaneous Microdialysis Cytokine Findings Supported by End Point Biopsy Immunohistochemistry Findings?

Journal Title: The AAPS Journal - Year 2010, Vol 12, Issue 4

Abstract

Insertion of a cutaneous microdialysis catheter into normal dermis has been shown to induce the production of IL1b, IL6 and IL8 in an innate response to minimal trauma. In the present study, skin biopsy for immunohistochemistry has been performed at the site of the microdialysis catheter to compare the findings with that of the microdialysis findings 24 h after insertion. Of the three named cytokines, concordance between the two investigated technologies was highest for IL8 (100%) followed by IL6 (70%) and IL1b (50%). For seven other pro-inflammatory and T cell-relevant cytokines studied, concordance ranged between 50% and 80%. The total number of positive (microdialysis or immunofluorescence) findings was similar between the two methodologies. Technical and biological phenomenon can explain the differences. We conclude that both methodologies illustrate important features of tissue biology and that a combination of the two methods in clinical research can provide the chronology of soluble mediator participation and the more classic, but also more invasive, biopsy-based methodology at a point which constitutes the end of the observation period. We conclude further that at the 24-h time period here studied, microdialysis catheters are still functional and thus capable of producing relevant data which can be corroborated and extended by the “end point biopsy”.

Authors and Affiliations

Florence Sjögren, Chris D. Anderson

Keywords

Related Articles

Bioanalytical Method Validation: Concepts, Expectations and Challenges in Small Molecule and Macromolecule—A Report of PITTCON 2013 Symposium

The concepts, importance, and implications of bioanalytical method validation has been discussed and debated for a long time. The recent high profile issues related to bioanalytical method validation at both Cetero Houst...

Spatial expression patterns of peptide transporters in the human and rat gastrointestinal tracts, Caco-2 In Vitro cell culture model, and multiple human tissues

This study sought to identify the spatial patterns of expression of peptide transporter 1 (PepT1), peptide transporter 3 (PTR3), peptide/histidine transporter 1 (PHT1), and the human peptide transporter 1 (HPT-1) mRNA in...

Microcalorimetric Method to Assess Phagocytosis: Macrophage-Nanoparticle Interactions

The online version of this article (doi:10.1208/s12248-010-9240-y) contains supplementary material, which is available to authorized users.

Inhibition of carboxyethylphosphoramide mustard formation from 4-hydroxycyclophosphamide by carmustine

It has been reported that the toxicity of carmustine (BCNU) cyclophosphamide (CY)/etoposide regimen (when BCNU is split into 4 doses) is less than that of BCNU/CY/cisplatin regimen (when the same amount of BCNU is admini...

Prediction of Biliary Excretion in Rats and Humans Using Molecular Weight and Quantitative Structure–Pharmacokinetic Relationships

The aims were (1) to evaluate the molecular weight (MW) dependence of biliary excretion and (2) to develop quantitative structure–pharmacokinetic relationships (QSPKR) to predict biliary clearance (CLb) and perce...

Download PDF file
  • EP ID EP681432
  • DOI  10.1208/s12248-010-9235-8
  • Views 86
  • Downloads 0

How To Cite

Florence Sjögren, Chris D. Anderson (2010). Are Cutaneous Microdialysis Cytokine Findings Supported by End Point Biopsy Immunohistochemistry Findings?. The AAPS Journal, 12(4), -. https://europub.co.uk/articles/-A-681432