Area and volume ratios for prediction of visual outcome in idiopathic macular hole
Journal Title: International Journal of Ophthalmology - Year 2017, Vol 10, Issue 8
Abstract
"AIM: To predict the visual outcome in patients undergoing macular hole surgery by two novel three-dimensional morphological parameters on optical coherence tomography (OCT): area ratio factor (ARF) and volume ratio factor (VRF). METHODS: A clinical case series was conducted, including 54 eyes of 54 patients with an idiopathic macular hole (IMH). Each patient had an OCT examination before and after surgery. Morphological parameters of the macular hole, such as minimum diameter, base diameter, and height were measured. Then, the macular hole index (MHI), tractional hole index (THI), and hole form factor (HFF) were calculated. Meanwhile, novel postoperative macular hole (MH) factors, ARF and VRF were calculated by three-dimensional morphology. Bivariate correlations were performed to acquire asymptotic significance values between the steady best corrected visual acuity (BCVA) after surgery and 2D/3D arguments of MH by the Pearson method with two-tailed test. All significant factors were analyzed by the receiver operating characteristic (ROC) curve analysis of SPSS software which were responsible for vision recovery. ROC curves analyses were performed to further discuss the different parameters on the prediction of visual outcome. RESULTS: The mean and standard deviation values of patients’ age, symptoms duration, and follow-up time were 64.8±8.9y (range: 28-81), 18.6±11.5d (range: 2-60), and 11.4±0.4mo (range: 6-24), respectively. Steady-post-BCVA analyzed with bivariate correlations was found to be significantly correlated with base diameter (r=0.521, P<0.001), minimum diameter (r=0.514, P<0.001), MHI (r= -0.531, P<0.001), THI (r=-0.386, P=0.004), HFF (r=-0.508, P<0.001), and ARF (r=-0.532, P<0.001). Other characteristic parameters such as age, duration of surgery, height, diameter hole index, and VRF were not statistically significant with steady-post-BCVA. According to area under the curve (AUC) values, values of ARF, MHI, HFF, minimum diameter, THI, and base diameter are 0.806, 0.772, 0.750, 0.705, 0.690, and 0.686, respectively. However, Steady-post-BCVA analysis with bivariate correlations for VRF was no statistical significance. Results of ROC curve analysis indicated that the MHI value, HFF, and ARF was greater than 0.427, 1.027 and 1.558 respectively which could correlate with better visual acuity. CONCLUSION: Compared with MHI and HFF, ARF could effectively express three-dimensional characteristics of macular hole and achieve better sensitivity and specificity. Thus, ARF could be the most effective parameter to predict the visual outcome in macular hole surgery."
Authors and Affiliations
Zhuang-Zhi Yan
A novel xeno-free culture system for human retinal pigment epithelium cells
"AIM: To find out an animal-free, xeno-free culture method for human fetal retinal pigment epithelium (fRPE) cells aiming for cell-replacement therapy. METHODS: Human AB serum, knock-out serum replacement (KSR) and B27 w...
Mechanism of delayed conduction of fellow eyes in patients with optic neuritis
To test the hypothesis that latency delay in the fellow eyes of optic neuritis (ON) patients and to compensate for delayed transmission of visual information, latency change of multi-focal visual evoked potential (mfVEP)...
Follow-up and multimodal imaging in long-chain 3-hydroxyacyl-CoA dehydrogenase deficiency
Letter to the editor
Mitochondrial expression and activity of P-glycoprotein under oxidative stress in outer blood-retinal barrier
"AIM: To investigate the role of oxidative stress in regulating the functional expression of P-glycoprotein (P-gp) in mitochondria of D407 cells. METHODS: D407 cells were exposed to different ranges of concentrations of...
Optical coherence tomography with or without enhanced depth imaging for peripapillary retinal nerve fiber layer and choroidal thickness
"AIM: To assess peripapillary retinal nerve fiber layer (RNFL) and choroidal thickness obtained with enhanced depth imaging (EDI) mode compared with those obtained without EDI mode using Heidelberg Spectralis optical coh...