Abstract

The complexity of the designing process of a switch disconnector framework comes from the almost impossible task to appreciate the discrepancy between the ideal and practical electric strength. Complicated geometries characterized by nonuniform fields are predesigned based on a set of analytical relations and corrected/optimized based on numerical methods and high voltage testing on prototypes. This paper suggest some approaches to minimize the effort and the steps required to achieve an acceptable stainless steel housing, in the insulators area, for a medium voltage SF6 switch disconnector. The results are based on simple analytical evaluation and finite element analysis in both 2D and 3D configurations.

Authors and Affiliations

Liviu Neamt, Olivian Chiver, Zoltan Erdei, Cristian Barz

Keywords

Related Articles

Decline of Active Power Loss by Improved Moth-Flame Optimization Algorithm

In this paper, Improved Moth-Flame Optimization (IMFO) algorithm has been proposed for solving Reactive power problem. Navigation method of moths in nature called transverse orientation is the key inspiration of the moth...

Structural Monitoring of Wind Turbines using Sensors Connected via UTP Cable

Unpredicted faults that may occur at the wind generators elements affect their economic operation. A promising approach that avoids these faults is the real-time vibrations monitoring. Data measured by the sensors can be...

Metrics for Energy Efficiency in Logistics of Freight Distribution

The paper is a study on the energy efficiency indicators that can be used for the activities in logistics of freight distribution, at the company level, as well as at macroeconomic level. There are highlighted also some...

A Modified Virtual Space Vector Modulation Technique for Z-Source NPC Inverters

A modified virtual space vector modulation approach for the control of a Z-source neutral point clamped inverter is presented in this paper. This approach works perfectly for the traditional neutral point clamped inverte...

Biot-Savart Law Application in Wireless Power Transfer – Dependence of Magnetic Field to Angle Position

The magnetic field of a closed loop of conductive wire can be computed due to Biot-Savart law, which analyses the value of the field at an exterior point from the transversal axis. If the measure point is out of the axis...

Download PDF file
  • EP ID EP314660
  • DOI -
  • Views 89
  • Downloads 0

How To Cite

Liviu Neamt, Olivian Chiver, Zoltan Erdei, Cristian Barz (2016). Aspects Regarding SF6 Switch Disconnector Framework Design. Carpathian Journal of Electrical Engineering, 10(1), 21-29. https://europub.co.uk/articles/-A-314660