Assessment of Medical X-Ray Radiographic Screen-Films in Different Spatial Frequencies According To Detective Quantum Efficiency Computation

Journal Title: International Journal of Fundamental Physical Sciences - Year 2012, Vol 2, Issue 1

Abstract

In medical imaging, to make better images there are some measures such as detective quantum efficiency (DQE) and noise equivalent quanta (NEQ) used to evaluate the image quality of each imaging system. Detective quantum efficiency (DQE) is one of the important measures in the assessment of image quality and detector performance. DQE of two types of screen-films namely Lanex Regular/T-Mat G/RA and Lanex Regular/T-Mat L/RA were determined using MTF and NPS data, separately. Moreover, gamma was calculated from characteristic curves for each screen film and photon flounce was estimated using published literature. DQE of the screen-films were computed for three optical densities 0.7, 1.0 and 1.4. The results show Lanex Regular/T-Mat G has better DQE than Lanex Regular/T-Mat L -especially at low frequency with higher contrast for diagnostic radiology purposes.

Authors and Affiliations

Mohammad Khanmirzaei, Wan Muhamad Wan Hassan

Keywords

Related Articles

Brownian Motion and Infrared Wave Force

The Brownian motion, thermodynamics performance and existence or non-existence of atmosphere in the earth ‎and other ‎celestial bodies depends on the effect of heat energy wave force i.e. Infra-red wave force on the oute...

Combined Investigations of Solar Bursts Type III and V

This review intended to update the results of combination two burst, type III and V in one solar flare event. Magnetic reconnection of both burst will be explained theoretically. Both bursts are found on 19th September 2...

Predicted Dynamic and Structural Criterion of Evaluation of Gravitational Waves

The cosmic (physical) vacuum according to modern data possesses the properties of a material medium. In combination with the celestial bodies, this medium is capable of forming dynamic structures. Presumably, these struc...

Existence of Positive Solutions For a Class of Multi-Point P-Laplacian Nonlinear System

In this paper, the existence of positive solutions for a class of p-Laplacian boundary value system is studied. In recent years, the boundary value problem has received a lot of attention. The fixed point theorems i...

A Comparison of the Influential Factors Creating Conflicts Between Cities and Its Annexed Village

Considering the lack of consistency in these urban and rural areas in relation to several factors such as social, economic, cultural, physical and administrative, the amalgamation of the rural areas into urban areas lead...

Download PDF file
  • EP ID EP599311
  • DOI 10.14331/ijfps.2012.330026
  • Views 108
  • Downloads 0

How To Cite

Mohammad Khanmirzaei, Wan Muhamad Wan Hassan (2012). Assessment of Medical X-Ray Radiographic Screen-Films in Different Spatial Frequencies According To Detective Quantum Efficiency Computation. International Journal of Fundamental Physical Sciences, 2(1), 9-11. https://europub.co.uk/articles/-A-599311