Abstract

The paper presents the research results of field measurements campaign of natural ventilation performance and effectiveness in a residential building. The building is located in the microclimate whose parameters differ significantly in relation to a representative weather station. The measurement system recorded climate parameters and the physical variables characterizing the air flow in the rooms within 14 days of the winter season. The measurement results showed that in spite of proper design and construction of the ventilation system, unfavorable microclimatic conditions that differed from the predicted ones caused significant reduction in the efficiency of the ventilation system. Also, during some time periods, external climate conditions caused an opposite air flow direction in the vent inlets and outlets, leading to a significant deterioration of air quality and thermal comfort measured by CO2 concentration and PMV index in a residential area.

Authors and Affiliations

Romana ANTCZAK-JARZĄBSKA, Marek KRZACZEK

Keywords

Related Articles

THE PROBLEM OF ADAPTING EXISTING RESIDENTIAL BUILDINGS IN THE COUNTRY TO THE REQUIREMENTS OF ECOLOGY

The article presents the results of direct research on residential buildings and their modernization in selected ecological farms of the Mazovia region. The research area covered two poviats (counties) in the Mazowieckie...

GEOTECHNICAL ISSUES OF SHALLOW MINING WITHIN THE UPPER SILESIAN INDUSTRIAL REGION

Mining activity, within the Upper Silesian Industrial Region resulted in numerous mining damage - especially the discontinuous deformations. They are developed in effect of shallow coal seams extraction or are connected...

INFLUENCE OF CYANOBACTERIAL BLOOM ON FRESHWATER BIOCOENOSIS. USE OF BIOASSAYS FOR CYANOBACTERIAL MICROCYSTINS TOXICITY ASSESSMENT

The issues presented in this study concern a very important problem of the occurrence of cyanobacterial blooms in surface water used for water supply purposes. The objective of this study was to analyze the occurrence of...

APPLICATION OF STEEL BAR BRACINGS IN RENOVATION AND MODERNIZATION OF HISTORIC BUILDINGS

The use of steel bracings is possible in all four stages of engineering activities in the renovation and modernization of historic buildings, i. e.: protecting, repairing, strengthening and rebuilding. Steel bracings are...

EQUILIBRIUM AND NON-EQUILIBRIUM FREEZING OF WATER IN CLAY-WATER SYSTEMS

The temperature of spontaneous nucleation Tsn and the equilibrium freezing point Tf were determined for six monomineral, homoionic clayey soils by use of the Differential Scanning Calorimetry (DSC) technique. The tempera...

Download PDF file
  • EP ID EP243228
  • DOI -
  • Views 93
  • Downloads 0

How To Cite

Romana ANTCZAK-JARZĄBSKA, Marek KRZACZEK (2016). ASSESSMENT OF NATURAL VENTILATION SYSTEM FOR A TYPICAL RESIDENTIAL HOUSE IN POLAND. Civil and Environmental Engineering Reports, 3(22), 25-44. https://europub.co.uk/articles/-A-243228