ASSESSMENT OF THE FACTORS INFLUENCING AND COMPARING THE INTRAOCULAR PRESSURE WITH THE HELP OF SCHIOTZ INDENTATION TONOMETER AND GOLDMANN’S APPLANATION TONOMETER: A CLINICAL STUDY

Abstract

Background: Intraocular pressure (IOP) is the fluid pressure inside the eye and is maintained by the equilibrium between the forces determining the formation of aqueous humour and the alteration in the resistance to its outflow. IOP is important to evaluate patients who are at an increased risk of glaucoma. Clinically measurement of IOP is based on principles of indentation and applanation and such a method is called Tonometry. The tonometers used today are the Schiotz Indentataion Tonometer (ST) and the Goldmann’s Applanation Tonometer (GAT). However the latter is accepted as the standard one. Aim: 1) To estimate the normal mean IOP for the population under study.2) To study the various factors- age, sex, refractive errors that influence the IOP.3) Merits and demerits of the individual tonometers. Method: A sample size of 100 cases of 200 sets of eyes was taken and divided into 2 groups, Group A with emmetropia, myopia, hypermetropia of both sexes and Group B with frank glaucomatous changes of both sexes. 3 consecutive measurements with GAT were recorded in each eye followed by ST with 5.5gm weight first followed by ST with 7.5gm weight. The whole database was recorded and statistically analysed. Results: Out of the total 200 eyes studied, Group A consisted of 168 apparently normal eyes which included emmetropes, myopes and hypermetropes and Group B comprised of 32 eyes which were frank glaucomatous cases with glaucomatous field defects. On estimating the mean IOP with the help of GAT and ST between the 2 eyes there was not a significant difference. On comparing the refractive status, myopes showed a higher IOP than hypermetropes and emmetropes. With both GAT and ST females had higher IOP than males. The mean IOP increased as age progressed. Group B studies which had frank glaucoma cases showed that the IOP measured with GAT was higher and more accurate to the actual IOP value whereas the readings with Schiotz were variable and unreliable. Conclusion: IOP is one of the key metrics which is used to monitor the health of one’s eye especially an eye with glaucoma. The IOP measured with GAT was more accurate towards the true intraocular pressure and hence Applanation Tonometer is considered gold standard in measuring IOP.

Authors and Affiliations

Mridula V Amarnath| Postgraduate, Department of Ophthalmology, Meenakshi Medical College, Kanchipuram, Tamil Nadu, India, Corresponding author email: mridulavenugopal.88@gmail.com, Christina Samuel| Postgraduate, Department of Ophthalmology, Meenakshi Medical College, Kanchipuram, Tamil Nadu, India, Sundararajan D| Professor & Head, Department of Ophthalmology, Meenakshi Medical College, Kanchipuram, Tamil Nadu, India

Keywords

Related Articles

Effect of Kinesio Taping on Motion, Pain with Functional Performance and Subsequent Quality of Life in Subject with Subacromial Impingement Syndrome

Background: This study examined the response of kinesio taping (KT) in combination with the conventional occupational therapy as compared to conventional occupational therapy alone on motion, pain with functional perfo...

Comparison Nokia, Samsung and Sony mobile phones in the specific absorption rate of head induced to electric field

The use of mobile phones has expanded in recent decades. Despite the extensive studies in this field, less attention has been paid to the biological effects of electromagnetic fields emitted by the mobile phones. Theref...

To investigate the relationship between stress, anxiety and depression with sexual function and its domains in women of reproductive age

Sexual function is really complicated and different factors including psychological matters can affect the performance of women. The aim of this study was to investigate the relationship between Stress, anxiety and dep...

A RARE CASE OF NEUROLIPOMA

A painful swelling over the left ankle joint was excised. Histopathology revealed it to be a neuroliploma. This case is reported here for its uncommon site that is involvement peroneal nerve, no association with skelet...

The Role of Attachment Styles and Resilience on Loneliness

This study investigated the relationship attachment styles and resilience have with loneliness in students. In this correlational study conducted in 2011, 200 students (132 women and 66 men) were selected through multis...

Download PDF file
  • EP ID EP11344
  • DOI 10.5958/2319-5886.2015.00010.7
  • Views 303
  • Downloads 12

How To Cite

Mridula V Amarnath, Christina Samuel, Sundararajan D (2015). ASSESSMENT OF THE FACTORS INFLUENCING AND COMPARING THE INTRAOCULAR PRESSURE WITH THE HELP OF SCHIOTZ INDENTATION TONOMETER AND GOLDMANN’S APPLANATION TONOMETER: A CLINICAL STUDY. International Journal of Medical Research & Health Sciences (IJMRHS), 4(1), 58-64. https://europub.co.uk/articles/-A-11344