Automated Gallery Lighting System and Seepage Water Control in Dam

Abstract

Now a day energy crisis in India is a critical issue. The present gallery lighting is controlled by manually and is leds to energy loss. The lighting system in the drainage gallery of the dam required during the maintenance work such as drilling and grouting the foundation. With the help of an automated lighting system, it reduces the power consumption of the lighting. This proposed system continuously monitors the pump’s which are used to pump the collected water from the storage tank due to seepage. The main aim of theautomated gallery lighting system is to reduce the power consumption when there is no person movement in the gallery and continuously monitors the pump. The automated gallery lighting system will turn ON the LED with the help of proximity sensor which is attached to the LED set when there is a person present in the gallery otherwise the LED lights will be switched OFF. This system operates in two modes i.e. remote mode and automated mode. In the automated mode with the help sensor, the LED get ON when person present within the sensor range and pump get started when seepage water more than the given limit to the float switch. In remote mode operation, the operator can ON the particular LED and Pump whenever required with the help of PLC programming common in PC or mobile. Things are becoming more simple and easier for everyone in the world today because of advancement of technology. The Automation system consisting of control and information unit that’s going to reduce the requirement of human need. The proposed system going to result in the power saving in an instant. The automated gallery lighting system provides a solution for energy saving, this can achieve by sensing an approaching person using the proximity sensor and then switching ON particular LED set on that range. As the person passes away from the particular range of the sensor the LED light set disconnected automatically with time delay. Buy this lot of energy get saved. In the present system, automated gallery lighting system light gets turned on automatically whenever the person enters the particular PIR sensor range. In order to decrease the problems of large energy consumption in an existing gallery lighting system, an automatic control system of gallery lighting is proposed. With the help of this system, it can save 80% of the energy consumption of the existing. The primary distinction between Microcontroller and PLC is that the PLC can operate in different a condition such as dust, moisture, heat, cold etc and the facility for extension of input and output arrangements

Authors and Affiliations

ABDULGAFFAR DODDAMANI

Keywords

Related Articles

Automated Gallery Lighting System and Seepage Water Control in Dam

Now a day energy crisis in India is a critical issue. The present gallery lighting is controlled by manually and is leds to energy loss. The lighting system in the drainage gallery of the dam required during the maintena...

SUPER CONDUCTING MAGNETIC ENERGY SYSTEM WITH DVR FOR VOLTAGE QUALITY IMPROVEMENT USING PSO BASED SIMPLE ABC FRAME THEORY

This paper illustrates the super conducting Magnetic Energy Storage (SMES) based Dynamic voltage restorer (DVR) with Proposed Simple ABC based PSO theory. Power quality is the most important in field of Distribution syst...

Eyeing the Human Brain’s Segmentation Methods

Image segmentation (IS) is often the first and most important step in medical image analysis. Among other uses, it helps us perform the following tasks in images: to measure and visualize the anatomical structures of the...

ENHANCEMENT OF STATIC FREQUENCY CONVERTER START-UP RELIABILITY FOR PUMPED STORAGE POWER UNITS OF GUANGZHOU PUMPED STORAGE POWER STATION

With the quick development of the power grid in Guangdong Province, pumped storage power stations have been developing in large capacity form of grid energy storage in Guangdong Power Grid for meeting the high electricit...

Automatic Solar Photovoltaic Battery Monitoring and Theft Control system

Being able to monitor the SPV battery remotely then it makes important to reducing time and cost associated with site visits. This is obviously especially important for an-off-grid system, which is often in even harder t...

Download PDF file
  • EP ID EP278251
  • DOI 10.24247/ijeeerfeb20181
  • Views 155
  • Downloads 0

How To Cite

ABDULGAFFAR DODDAMANI (2018). Automated Gallery Lighting System and Seepage Water Control in Dam. International Journal of Electrical and Electronics Engineering Research (IJEEER), 8(1), 1-10. https://europub.co.uk/articles/-A-278251