Automation of Electrical Isolators/ Disconnector using Electrical Motor and Gearbox

Journal Title: GRD Journal for Engineering - Year 2017, Vol 2, Issue 4

Abstract

Electrical Isolators have been used primarily before circuit breakers in a power transmission substation. Circuit Breakers are used to isolate the circuit. The break points cannot be viewed externally as they lie within the circuit breaker. Electrical Isolators are therefore physical switches that are in place to ensure that the complete connection or disconnection to the whole circuit is made. It is very essential safety switch. These Electrical Isolators used in substations are manually handled, to open or close the Electrical Isolator/ Disconnector switch. This process is hazardous for the person operating the Isolators/ Disconnectors. Therefore, to automate the operation an electric motor can be used. This motor can be used to operate the Electrical Isolator/Disconnector switch remotely. A gear box needs to be designed to give necessary output speed needed to operate the electrical Isolator/Disconnector switch mechanism. Hence, in this project a speed reducer gearbox has been designed for two electrical motors with powers: 0.5 HP and 1 HP. The gearbox uses spur gear pair and worm gear pair to get the necessary output speed.

Authors and Affiliations

Yash Abhang, Anuj Kadam, Anas Qureshi, Swapnil Kale, Digvijay Mahajan

Keywords

Related Articles

Mathematical Modelling of Switched Reluctance Motor

The SRM is a doubly salient machine with very high torque to inertia ratio and high fault tolerant capability. SRM is widely used in low, medium and high power drives and high speed drives. This paper describe a mathemat...

Urban Trip Rate Modeling for The Recently Expanded Areas: A Case Study of Surat

The rapid urbanization in our metropolitan cities has resulted in simultaneous expansion of cities in spatial dimension. The impact is also on the city infrastructure required for various sectors including transportation...

Assessment of VOC Emission at West Zone Transfer Station of Surat City

Municipal Solid Waste Management is associated with the control of generation, collection, storage, transfer and transport, processing and disposal of solid wastes. Concentration of VOC emissions were measured at major t...

Advanced Electronic Walking Stick for Blind

Visually impaired persons find themselves challenging to go out independently. White cane have been used to assist the blind people’s navigation. With advancement in technology electronic walking sticks with obstacle det...

Comparative Study of Typical R.C. Building using Indian Standards and Euro Standards under Seismic Forces

In R.C. buildings, frames are considered as main structural elements, which resist shear, moment and torsion effectively. These frames are subjected to variety of loads, where lateral loads are always predominant. Infras...

Download PDF file
  • EP ID EP224346
  • DOI -
  • Views 74
  • Downloads 0

How To Cite

Yash Abhang, Anuj Kadam, Anas Qureshi, Swapnil Kale, Digvijay Mahajan (2017). Automation of Electrical Isolators/ Disconnector using Electrical Motor and Gearbox. GRD Journal for Engineering, 2(4), 64-67. https://europub.co.uk/articles/-A-224346