[b]Design and Construction of a Model Sedimentaion Tank Using Existing Slow Sand Filter For NDA Treatment Plant[/b]

Abstract

The treatment of water for human consumption involves various processes in which raw water passes through. This processes includes; screening, flocculation/coagulation, sedimentation, filtration and chlorination. Sedimentation is a process between flocculation/coagulation tank and filtration tank. The design of sedimentation tank is necessary to receive effluent of the flocculation/coagulation tank and achieve efficient settling of particles under gravity and then discharge to the slow sand filter as effluent for further treatment. To achieve this grate settling efficiency, a rectangular sedimentation tank withthe following dimensions; depth 3.58m, width 5.76m and 23.0m long, is designed and constructed with a baffle across the inlet perforated with holes, this provides calm area at the settling zone for efficient settling of particles. The base of the tank is sloped towards the inlet zone for collection and disposal of sludge gate valve. While at the outlet zone, a baffle is provided to prevent any particle which did not settle from going out.

Authors and Affiliations

A Saminu

Keywords

Related Articles

 SUPER-RESOLUTION RESTORATION OF VIDEO SEQUENCES: A SURVEY

 Several competing methodologies are emerging in the field of video processing regarding the super-resolution (SR) restoration of video sequences. The narrowly associated problem of erection of SR still images from...

 THE EFFECT OF HYBRIDIZATION ON MECHANICAL PROPERTIES OF PINE APPLE LEAF FIBRE (PALF) AND COIR FIBRE

 The availability of Composite materials and natural Fibre is abundance and also they are very inexpensive when compared to other advanced man-made Fibre. These natural Fibre s are used as a suitable reinforcing mat...

 SEISMIC VULNERABILITY ASSESSMENT OF BUILDINGS IN HYDERABAD CITY

 India has a range of the world’s greatest earthquakes in the last century. Assuredly, quite one-half space within the country is considered at risk of damaging earthquakes. The northeastern region of the country a...

Weather Parameters Monitoring based on Zigbee and AVR Microcontrollers

This paper focuses on using Atmel AVR series of microcontrollers and TarangZigbee module to monitor the Environmental parameters such as temperature, humidity, CO2, and moisture level of an Environment wirelessly.Nowad...

 Fault Diagnosis of Ball Bearing using Time Domain Analysis and Fast Fourier Transformation

 In this study Fault diagnosis of Ball bearings is done by statistical analysis under various time domain parameters. The objective of this study is to investigate the correlation between time domain and frequency...

Download PDF file
  • EP ID EP132979
  • DOI -
  • Views 86
  • Downloads 0

How To Cite

A Saminu (30). [b]Design and Construction of a Model Sedimentaion Tank Using Existing Slow Sand Filter For NDA Treatment Plant[/b]. International Journal of Engineering Sciences & Research Technology, 2(7), 1694-1699. https://europub.co.uk/articles/-A-132979