Beam commissioning data and Quality assurance test for Linear accelerator

Journal Title: Journal of Indira Gandhi Institute of Medical Sciences - Year 2015, Vol 1, Issue 2

Abstract

Abstract: During commissioning of a modern linear accelerator (LINAC) for clinical and research purpose, medical physicists were faced with many challenges, like a variety of scientific testing methods, data accuracy etc. Since final beam data obtained during commissioning are treated as references and ultimately used for radiotherapy treatment, it is vital that collected data are of very high quality. The scientific procedure used for commissioning of LINAC at Mahavir Cancer Santhan,Patna has been described in detail in this article. The maximum beam energy of this LINAC is 15 MV for photons and 12 MeV for electrons. The approximate flux of the source are of the order 1018 photons/sec and 1020 electrons/sec with a highest delivery dose rate of 500 cGy/min for photons and 400 cGy/min for electrons at the dose maximum point in the water phantom. In this article, a complete set of measured data of the LINAC has been presented. The measured radiation data are within permissible limit. A modern linear accelerator has been commissioned and is being used for therapeutic purposes and material modification by irradiation since last three years. Some successful applications in the field of treatment and material modification of the machine have also been presented in this article.

Authors and Affiliations

Mukesh Kr. Zope, Deepali Patil, Rajesh Kumar Singh, B. B. Prasad

Keywords

Related Articles

ACQUIRED VAGINAL STENOSIS WITH SECONDARY INFERTILITY; A RARE COMPLICATION OF TRAUMATIC PPH

Abstract Secondary gynaetresia may occurs due to trauma to the female genital tract with secondary infection and adhesions. Post traumatic vaginal stenosis after full term vaginal delivery is rarely seen in gynaecologica...

Free vascularized fibular graft for osteonecrosis of femoral head

Abstract Osteonecrosis of the femoral head is a challenge for all the orthopedic surgeons. There are many treatment modalities for the problem but there is lack of clear superior method of treatment. FVFG can arrest the...

A RARE BILATERAL VARIATION OF THE ANTERIOR BELLY OF DIGASTRIC MUSCLE

ABSTRACT : The digastric muscle is a suprahyoid muscle which consists of two bellies: anterior & posterior. Above the hyoid bone these two bellies are connected by an intermediate tendon, which is anchored to the hyoid b...

A Case Report of Retroperitoneal Dermoid

Abstract Primary dermoid of retroperitoneal space is exceedingly uncommon. Primary dermoid, mainly occurs in gonads (testes and ovaries), mostly in adults. Extragonadal dermoids are less common, mainly occur in infants...

Rheumatological Manifestations in Diabetic Population from Bihar

Abstract Rheumatological disorders in diabetic patients are generally neglected, but their prevalence is quite high in diabetic patients. This was an observational, prospective hospital based study conducted on 200 diab...

Download PDF file
  • EP ID EP288940
  • DOI -
  • Views 83
  • Downloads 0

How To Cite

Mukesh Kr. Zope, Deepali Patil, Rajesh Kumar Singh, B. B. Prasad (2015). Beam commissioning data and Quality assurance test for Linear accelerator. Journal of Indira Gandhi Institute of Medical Sciences, 1(2), 19-22. https://europub.co.uk/articles/-A-288940