Bioaerosol assessment in naturally ventilated historical library building with restricted personnel access

Journal Title: Annals of Agricultural and Environmental Medicine - Year 2011, Vol 18, Issue 2

Abstract

The aim of this study was to check the degree and identify the sources of microbial contamination of the Jasna Góra (Bright Hill) monastery library 10 years after disinfection of the incunabula collection. The registered maximum viable indoor microbial concentrations were 1,875 and 7,100 cfu/m[sup]3[/sup] for stationary and personal measurements, whereas respective total concentrations were 71,000 and 100,000 counts/m[sup]3[/sup] . There was no statistically significant difference between the concentrations of viable microorganisms measured in the stationary using Andersen, GSP, and Button samplers. Moreover, GSP and Button samplers can be interchangeably applied when viable or total microbial levels are stationary or personally measured. The culturable microorganisms constituted 0.5 - 3.9% of the total microflora only. Filamentous fungi were the most prevalent outdoors, whereas Gram-positive cocci and endospore forming Gram-positive rods dominated indoors in the air and settled dust, respectively. Hence, an unrestrained infiltration of ambient air through the draughtiness of the building envelope is probably the main process responsible for indoor fungal pollution, whereas bacterial contaminants have their major sources in the indoor environment. Moreover, even a chemically cleansed library collection, having a restricted personnel access, but under the influence of ambient air, can undergo microbial contamination and becomes an important microbial emission source.

Authors and Affiliations

Aleksander Harkawy, Rafał L. Górny, Leonard Ogierman, Agnieszka Wlazło, Anna Ławniczek-Wałczyk

Keywords

Related Articles

The first evidence for vertical transmission of [i]Babesia canis[/i] in a litter of Central Asian Shepherd dogs

[b]Introduction and objective[/b]. Tick-borne infections constitute an increasing health problem in dogs and may lead to death, especially in young or elderly individuals. Canine babesiosis constitutes a serious health p...

Microbial air contamination in indoor environment of a university library

The present study was aimed at evaluating the number of bacteria and mould fungi in the indoor and outdoor environment of Toruń University Library. The sampling sites were located in the rooms serving the functions typic...

Epidemiology of human toxocariasis in Poland – A review of cases 1978–2009

Toxocariasis is a helminthozoonosis due to the infection of humans with larvae belonging to the [i]Toxocara[/i] genus. Humans become infected as a result of accidental consumption of infected eggs containing third stage...

Designer Drug (DD) abuse in Poland; a review of the psychoactive and toxic properties of substances found from seizures of illegal drug products and the legal consequences thereof. Part 1 – Cannabinoids and Cathinones

Faced with the rapidly growing increase of designer drug abuse, particularly amongst the younger generation, various legislative strategies are currently employed world-wide for tackling this problem – however with mixed...

Risk of exposure to airborne Ambrosia pollen from local and distant sources in Europe – an example from Denmark

[b][/b][b]Background. [/b][i][/b]Ambrosia artemisiifolia[/i] L. is a noxious invasive alien species in Europe. It is an important aeroallergen and millions of people are exposed to its pollen. Objective. The main aim o...

Download PDF file
  • EP ID EP80397
  • DOI -
  • Views 106
  • Downloads 0

How To Cite

Aleksander Harkawy, Rafał L. Górny, Leonard Ogierman, Agnieszka Wlazło, Anna Ławniczek-Wałczyk (2011). Bioaerosol assessment in naturally ventilated historical library building with restricted personnel access. Annals of Agricultural and Environmental Medicine, 18(2), 323-329. https://europub.co.uk/articles/-A-80397