Bioelectrode based chitosan-nano copper oxide for application to lipase biosensor

Journal Title: Journal of Applied Pharmaceutical Research - Year 2017, Vol 5, Issue 1

Abstract

Chitosan (Chit)-nanocrystalline CuO composite prepared from Chitosan and CuO nanoparticles by a spin coating method. CuO nanoparticles (45 nm) synthesized by Sol-gel citrate method and characterized by X-Ray diffraction (XRD), Raman spectroscopy, UV-visible spectroscopy, Fourier transform spectroscopy (FTIR) and Scanning electron microscopy (SEM). The electrochemical studies revels that these Chit-nano CuO electrode provide favorable condition for immobilization of enzyme lipase [LIP] specific enzyme for triglyceride detection, resulting in enhanced electron transfer at the interface. The prepared bioelctrode (LIP/Chit-nano CuO/Au bioelectrode) is utilized for triglyceride [TG] sensing using cyclic voltammetry (CV) with hexacyanoferrate as mediator. The electrochemical response studies shows on improved sensing performance of bioelectrode exhibit high sensitivity, low detection limit and good linearity of tributyrin concentration with fast response time. The low value of Michallis-Menten constant indicates high affinity of LIP towards the analyte (tributyrin). The Redox behavior of nano CuO makes an efficient matrix with chitosan for triglyceride [TG] biosensor

Authors and Affiliations

A. B. Bodade, M. A. Taiwade, G. N. Chaudhari

Keywords

Related Articles

In-vitro anti tubercular activity of flowers of Couroupita guanensis L.

Modern civilization is facing hundreds of disorders associated with microorganisms. The natural phytochemicals fromnon-edible plants are gaining importance to fight against these disease The intention of this study is to...

Statistical optimization of compression coated ketoprofen tablet using amylose/ethyl cellulose mixture for colonic delivery

In the present study the effect of two independent factors (amount of ethyl cellulose in coating layer and coating level) on ketoprofen release from compression coated tablet in order to optimize coated tablet for coloni...

Bioelectrode based chitosan-nano copper oxide for application to lipase biosensor

Chitosan (Chit)-nanocrystalline CuO composite prepared from Chitosan and CuO nanoparticles by a spin coating method. CuO nanoparticles (45 nm) synthesized by Sol-gel citrate method and characterized by X-Ray diffraction...

Cucumis sativus (cucumber): a review on its pharmacological activity

Medicinal plants have been used for centuries, and numerous cultures still rely on plants for their primary health care needs. In the recent past there has been a tremendous increase in the use of plant based health prod...

Stilbenes: chemistry and pharmacological properties

Medicinal plants are the most important source of life saving drugs for the majority of the Worlds’ population. The compounds which synthesized in the plant from the secondary metabolisms are called secondary metabolites...

Download PDF file
  • EP ID EP211865
  • DOI -
  • Views 215
  • Downloads 0

How To Cite

A. B. Bodade, M. A. Taiwade, G. N. Chaudhari (2017). Bioelectrode based chitosan-nano copper oxide for application to lipase biosensor. Journal of Applied Pharmaceutical Research, 5(1), 30-39. https://europub.co.uk/articles/-A-211865