Biomechanical simulation of needle insertion into cornea based on distortion energy failure criterion

Journal Title: Acta of Bioengineering and Biomechanics - Year 2016, Vol 18, Issue 1

Abstract

Purpose: This paper is mainly about biomechanical behavior of needle insertion into cornea, and proposes a failure criterion to simulate the insertion process which has attracted considerable attention due to its importance for the minimally invasive treatment. Methods: In the process of needle insertion into cornea, tiny and complex insertion force is generated due to contact between needle and soft tissue. Based on the distortion energy theory, proposes a failure criterion of corneal material that can solve contact problem between rigid body and biological tissue in insertion simulation, where Cauchy stress of corneal material is the key to numerical calculation. A finite element model of in vivo cornea is built, and the cornea constrained by sclera is simplified to two layers containing epithelium and stroma. Considering the hyper-viscoelastic property of corneal material, insertion simulation is carried out. Results: By insertion experiment, the insertion force increases with insertion depth accompanying obvious fluctuations. Different insertion forces are generated at different speeds. The punctured locations are obvious in the force-displacement curves. The results of insertion simulation are generally consistent with experimental data. Maps of von-Mises stress reflect the tissue injury of the cornea during insertion process, and punctured status corresponds to the point in the curves. Conclusions: The ability of this study to reproduce the behavior of needle insertion into cornea opens a promising perspective for the control of robotic surgery operation as well as the real-time simulation of corneal suture surgery.

Authors and Affiliations

Keywords

Related Articles

The novel method to calculate mechanical properties of cancer cells based on atomic force microscopy

Purpose: Mechanical properties, as the inherent characteristics of cells, play a critical role in many essential physiological processes, including cell differentiation, migration, and growth. The mechanical properties o...

Muscle torque of healthy individuals and individuals with spastic hemi paresis after passive static stretching

Spasticity is one of the main causes of contracture, muscle weakness and subsequent functional incapacity. The passive static stretching can included as having the purpose of increasing musculoskeletal flexibility, howev...

Effects of the microcrack's shape, size and direction on the poroelastic behaviors of a single osteon: a finite element study

Purpose: In this work, a finite element study is proposed by using the Comsol Multiphysics software to evaluate the effects of microcrack's shape, size and direction on the poroelastic behaviors of a single osteon. Metho...

Measuring the force of punches and kicks among combat sport athletes using a modified punching bag with an embedded accelerometer

The main aim of the study was to design a new system to measure punching and kicking forces as well as reaction times in combat sport athletes. In addition, the study examined whether there were any intergender differenc...

Experimental study of the loss of balance process before falling from a height

Due to a high number of accidents at work, actions have been undertaken to apply numerical simulation for reconstruction of their course in time. First works on this issue showed that the numerical human body model devel...

Download PDF file
  • EP ID EP206842
  • DOI 10.5277//ABB-00248-2014-02
  • Views 74
  • Downloads 0

How To Cite

(2016). Biomechanical simulation of needle insertion into cornea based on distortion energy failure criterion. Acta of Bioengineering and Biomechanics, 18(1), -. https://europub.co.uk/articles/-A-206842