Bolus silicone rubber with 2% silica composite for radiotherapy application
Journal Title: International Journal of Allied Medical Sciences and Clinical Research - Year 2018, Vol 6, Issue 3
Abstract
Bolus is a device in external radiotherapy to increase a surface dose using electron beam. In this research, bolus was synthesized using silicone rubber (SR) and silica composite with dimension of 12 cm x 12 cm x 0.5 cm. In bolus synthesis, the SR mass was used with amount of 73 gram and catalyst volume with amount of 4 ml. Silica composite was added with 2% from SR mass, all of sample was mixed and poured into the mold and waited until the sample was completely hard and ready to lift from the molding. Bolus was charaterized using linear accelerator (LINAC) with electron beam to obtained a percentage of surface dose (PSD) in solid phantom surface and the electron beam energy were used 5 MeV and 7 MeV. The result show that the PSD value was increased with adding silica composite with PSD value are 105.55% and 99.76% for energy 5 MeV and 7 MeV, respectively.
Authors and Affiliations
Santi Yuli Astuti
A case report on compressive myelopathy
Compressive cervical myelopathy is referred as a neck condition that arises when the spinal cord becomes squeezed due to the wear-and-tear changes that occur in the spine with advancing age. Etiological factors for this...
Prevalence of non-fermenter as uro pathogen in tertiary care hospital in Chidambaram, Tamil nadu
Background and Objectives: Aerobic, nonfermenting gram-negative bacilli (non-fermenters) are now emerging as important uropathogens. This study was done to know the prevalence of non-fermenters in Urinary Tract Infection...
Early detection of chronic obstructive pulmonary disease in asymptomatic smokers using spirometry – a hospital based study
Background Smokers with suspected COPD seek medical attention when they become dyspnoeic on mild to moderate exertion, but by than half of the ventilatory reserves are lost irreversibly. Hence it seems logical to diagnos...
To study pulmonary function in traffic and city police of Jalgaon city
he purpose of this study is to check pulmonary function in traffic and city police of jalgaon city. 120 policemen were selected in the study with age group 30 to 60 years with minimum 5 years of experience for duration o...
Prevalence of the transfusion transmissible infections among blood donors in a blood bank at a tertiary care teaching hospital in north India
Background Transfusion of blood and its components is a life saving measure in various medical and surgical emergencies. Transfusion carries the risk of transmitting the life threatening transfusion transmissible infecti...