Bone tissue loads around titanium femoral implant and coated with porous layer
Journal Title: Journal of Achievements in Materials and Manufacturing Engineering - Year 2018, Vol 2, Issue 90
Abstract
Purpose: Difference in the mechanical properties of bone and stiffer femoral implant causes bone tissue resorption, which may result in implant loosening and periprosthetic fractures. The introduction of porous material reduces the stiffness of the implant. The aim of the study was to analyse the influence of porous shell of femoral revision implant on bone tissue loading distribution with use the finite element method. Design/methodology/approach: Load transfer in the femur has been investigated using the finite element method (Ansys). Cementless implant models were placed in the anatomical femur model. Femur model included sponge bone and cortical bone. The solid implant was compared with the implant containing porous material in 70% in outer layer with a thickness of 2 mm. Load of 1500 N during gait was simulated. In addition, the forces of the ilio-tibial band and the abductor muscles were implemented, as well as the torque acting on the implant. Findings: Increase of stress for the porous model was found. The underload zones in bone have been reduced. Loading distribution was slightly more favourable, albeit rather in cortical bone. Stress value in cancellous bone around cementless implant margin has increased to a level that is dangerous for bone loss. Stress in the implant was not dangerous for damage. The stress distribution was different in the implant neck zone where the porous shell borne a little less load and high stress was shifted to the stiffer core. Research limitations/implications: Variable conditions for fitting the stem to the bone as well as the friction conditions were not investigated. Practical implications: Stress values in the spongy bone around the insertion edge of the cementless implant are consistent with long-term clinical results of the bone atrophy in 1 and 2 Gruen`s zones around the fully porous implants. Originality/value: The advantage of fully porous coated implant was the decrease of risk of trabecular bone tissue resorption around the implant tip and the increase of risk of trabecular bone tissue resorption around insertion edge of the implant.<br/><br/>
Authors and Affiliations
G. Bobik, J. Żmudzki, K. Majewska
Temperature impact on delayed fracture of creep-resistant steels welds
Purpose: Phenomenon of delayed fracture (or cold cracks formation) of hardenable steels weldments had been widely investigated. But temperature dependence of cracking susceptibility remained discussable, because there wa...
Microstructure, microhardness and tensile properties of FSWed DP 800 steel
Purpose: Dual phase (DP) steels are widely used in the automotive industry due to their properties of a high balance of strength and formability. However, it is known that conventional welding of high strength steel lead...
Preparation of biomimetic superhydrophobic coating on mild steel
Purpose: Superhydrophobic surface has many special functions and is widely investigatedby researchers. Mild steel is one among the practice metals and plays an importantrole in all industrial applications. In this work,...
Enhancing bio-gas production from kitchen waste using BSA-iron oxide nanoparticles in miniature level bio-reactor
Purpose: This study focuses on increasing production of biogas as an alternative energyfrom biodegradable wastes (BWs) using BSA coated iron oxides nanoparticles, in view ofsolving waste management at household level. Ma...
Single-frequency induction hardening of structural steel
Purpose: Current paper presents investigation of specimens after single frequency induction hardening process. The main aim is to compare microstructure of the material after the process conducted with different voltage...