بررسي خاک اره اصلاح شده با دياتيلنتريآمين بهعنوان يک جاذب مؤثر براي حذف آهن (III) از نمونههاي آبي
Journal Title: آب و فاضلاب - Year 2018, Vol 29, Issue 2
Abstract
Evaluation of the Sawdust Modified with Diethylenetriamine as an Effective Adsorbent for Fe (III) Removal from Water Heavy metals are environmental pollutants that nowadays a lot of efforts are made to remove them. In this research, the sawdust modified with diethylenetriamine as an effective adsorbent for Fe (III) removal from water samples was conducted. First, the sawdust was modified by diethylenetriamine. SEM analysis showed that the particle surface is changed by modification. Then the effective factors in Fe (III) removal such as pH, adsorbent dose, shaker speed and contact time were studied and optimized. The optimum conditions were employed for various Fe (III) concentrations (20–300 mg L-1) and in all cases, the removal rate was significant. The adsorbent has high capacity for Fe (III) removal in a way that it removed more than 95.0±0.3 % of Fe (III) (50 mg/L) by 1.5 g/L of adsorbent in 15 minutes. The Langmuir and Freundlich isotherms were applied to the adsorption process and their constants were evaluated. The adsorption equilibrium data fitted well to Langmuir isotherm. The maximum Langmuir adsorption capacity of Fe (III) ions was 200.0 mg/g. According to kinetics experiments of Fe (III), the adsorption process had more conformity to pseudo-second-order kinetic model. This method was successfully applied for Fe (III) removal from potable water, well water, river water and industrial wastewater samples. Fe (III), Modified Sawdust, Removal, Diethylenetriamine, Langmuir Isotherm.
Authors and Affiliations
Azita Ostovan, Shahla Elhami
پيامد هوموسي شدن کاه گندم و توانايي ريزجانداران آن بر جذب زيستي سرب از يک آب آلوده
Adsorption of Pb(II) from Aqueous Solutions on Wheat Straw: Effects of Humification and Sterilization Abstract Biosorption is one of the methods used for the separation of heavy metals from aquatic environments. The ob...
ارزيابي خطرپذيري تصفيهخانههاي آب با استفاده از تحليل درخت خطاي فازي (مطالعه موردي: تصفيهخانه جلاليه تهران) Risk Assessment of Water Treatment Plants Using Fuzzy Fault Tree Analysis (Case Study: Jalaliyeh Water Treatment Plant)
Abstract In this research, Fault Tree Analysis (FTA) with fuzzy and crisp approaches were used to assess the risk associated with the performance of water treatment plants. The fuzzy logic was used to consider the uncer...
بررسي ميزان آرسنيک موجود در منابع آبي روستاهاي شهرريوش و مقايسه با استانداردهاي موجود با استفاده از GIS
GIS-based Assessment of Arsenic Contamination of Water Supplies in Rural Areas of Rivash Town: Comparisons with National and WHO Standards Arsenic is one of the most hazardous elements in drinking water. Water contaminat...
پتانسيل استفاده مجدد از آب براي مصارف خانگي: بخش سوم- فرصتها و چالشها Potential Application of Reclaimed Water for Potable Reuse: Part III- The Path Forward and Implementation Challenges
Abstract This paper (Part III) is the third in a series of three papers on potential application of water reuse for potable use. Introductory and background material on potable water reuse was presented in Part I. Tech...
Analyzing Productivity Indices for Urban Water and Wastewater Companie تحليل شاخصهای بهرهوری شرکتهای آب و فاضلاب شهری
Abstract Major investments and high operational expenditure are the special characteristics of the water and wastewater industry in the context of organizational mission. Planning the production and improving the effici...