Calculation Method for Tunnel Fire Smoke Exhaust Volume with Point Smoke Exhaust Mode

Journal Title: Urban Mass Transit - Year 2024, Vol 27, Issue 7

Abstract

Objective To address the lack of recognized numerical values and calculation methods for smoke exhaust volume of tunnel fire point smoke exhaust system specialized in GB 50016—2014 ′Code for fire protection design of buildings′, a definition of critical smoke exhaust volume and relevant calculation methods are proposed. Method A force analysis of smoke beneath vent is conducted using the Froude number, which characterizes the relative magnitude of buoyancy force and inertia force, as the theoretical criterion for determining the critical smoke exhaust volume. Based on this criterion, the intrinsic relationship between the relative magnitude of buoyancy and inertia forces, and the smoke gas deviation trajectory is further analyzed. Combined with model test data, a semi-empirical model for the critical smoke exhaust volume is established. Result & Conclusion The Froude number for determining the critical smoke exhaust volume is independent of the spacing between vents and the heat release rate of fire, but is related to the ratio of smoke layer thickness to vent length. When this ratio is greater than 0.67, the Froude number exhibits a power function relationship with the ratio of smoke layer thickness to vent length. Conversely, when this ratio is less than or equal to 0.67, the Froude number is linearly correlated with the ratio of smoke layer thickness to vent length.

Authors and Affiliations

Rui WANG

Keywords

Related Articles

Treatment of Mud Inrush Disasters and Risk Control for Underground-excavated Metro Tunnel in Self-weighty Saturated Slump Loess Ground Fissure

Objective Saturated loess slump may lead to underground cavity. When the underground tunnel passes through the fortified fissures section of the self-weighty saturated slump loess site, the encountered underground cavity...

Rail Transit Fare Calculation and Settlement Rules Based on Complex Interoperation Scenarios in Guangdong-Hong Kong-Macao Greater Bay Area

Objective Conventional fare calculation and settlement rules are not suitable for the complex interoperation scenarios of rail transit network in the Guangdong-Hong Kong-Macao Greater Bay Area (GBA). To ensure the accura...

Construction and Application of Knowledge Graph for Train Maintenance Field

Objective With its powerful semantic processing and open organization capabilities, the knowledge graph lays the foundation for knowledge-based organization and intelligent applications in various fields. In order to imp...

Prediction Model for Gravel Stratum Shield Cutter Wear and Parameter Sensitivity Analysis of Cutter Parameters

[Objective] The high volume fraction of quartz particles in gravel stratum can lead to significant wear of shield cutters, impacting construction progress and timelines. Establishing a prediction model for shield cutter...

Research on Real-time Wheel-rail Force Identification Network of Rail Transit under Compound Line Conditions

Objective Wheel-rail force plays an important role in the study of train running state, wheel off roundness and rail corrugation in rail transit. Current wheel-rail force identification methods have some problems, such a...

Download PDF file
  • EP ID EP742597
  • DOI 10.16037/j.1007-869x.2024.07.013
  • Views 15
  • Downloads 0

How To Cite

Rui WANG (2024). Calculation Method for Tunnel Fire Smoke Exhaust Volume with Point Smoke Exhaust Mode. Urban Mass Transit, 27(7), -. https://europub.co.uk/articles/-A-742597