Calculation of Air Exchange to Reduce CO2 by Periodic Ventilation of Cattle Buildings

Abstract

The outdoor cattle keeping permits changing the air exchange intensity to prevent hazards during the day. It is important to organize such air exchange during the outdoor run which would provide the required air quality, including the CO2 concentration in the internal airspace by the moment of the cattle’s return to the stalls. The analytical solution of the problem of determining the changes in the average airspace CO2 concentration for a certain period of time at predetermined air exchange intensity is considered in the article

Authors and Affiliations

В. Fediai, D. Guzyk

Keywords

Related Articles

Numerical Study of Aerodynamic Processes in the Furnace Water-tube Boiler at Different Operating Conditions

The results of numerical studies of aerodynamics of the furnace of water-tube steam boiler DE-10/14 are presented. The boiler is equipped by vortex gas-oil burner GMG-7 performing 718 m3/h of natural gas. Calculations of...

Standardization of Ultraviolet Irradiation of Rooms and Territories by Energy Criterions

Compaction of building attended by appearance of negative factors in quality of habitat environment especially of light-insolation condition. In modern Ukrainian standards, criterion of ultraviolet radiation estimation i...

Analytical description of the expansion of wall jets of different curvature

The work is devoted to an analytical study of the expansion of wall jets on a convex and concave surfaces (curved semi-limited jets). Such jets have different characteristics depending on the curvature of the surface - f...

Features of Using the Regulatory Method "Thermal Calculation of Boiler Units" for Firetube Boilers

In recent years, the practice of using fire-tube and fire-fighting water-heating boilers in the replacement of service water heating boilers in boiler-houses has become commonplace in the district heating systems of the...

Influence of magnetic field characteristics during water treatment on the parameters of capillary-porous and colloidal capillary-porous bodies

Technological systems with water magnetization give unstable results. The reason is a lack of research of the influence of the water magnetization parameters. The hypotheses on expediency of application of high-frequency...

Download PDF file
  • EP ID EP556978
  • DOI -
  • Views 60
  • Downloads 0

How To Cite

В. Fediai, D. Guzyk (2016). Calculation of Air Exchange to Reduce CO2 by Periodic Ventilation of Cattle Buildings. Вентиляція, освітлення та теплогазопостачання, 20(), 54-61. https://europub.co.uk/articles/-A-556978