Calculation Parameters for Cooling Period in Ukraine
Journal Title: Вентиляція, освітлення та теплогазопостачання - Year 2018, Vol 24, Issue
Abstract
To ensure the completeness of the original data when designing ventilation systems, air conditioning systems and surface cooling in buildings with minor (up to 10 w/m2) heat gains, air moisture content was determined in July for regional cities of Ukraine based on analytical processing the existing regulatory data of climatic parameters. Moisture values, characteristic temperatures start and finish dates for cooling period in conjunction with other climate parameters, according to DSTU-N B V.1.1-27:2010, can be used to design and assess monthly, seasonal and annual heat consumption for microclimate providing systems in rooms, simplify the calculation methods of energy consumption for cooling and air-conditioning systems according to DSTU B A.2.2-12:2015. The proposed dates for the beginning and the end of cooling period, like dates of heating period, will ensure on time preparation of engineering systems of buildings to their seasonal operation etc. Based on the proposed temperature-time characteristics of cooling period, there is a corresponding rating of Ukrainian regional cities, which can describe the amount of expenses on the cooling system of the premises and buildings. Obtained table data is recommended for wide use in practice of design and maintenance of microclimate providing systems
Authors and Affiliations
O. Liubarets
Energy Efficient System of Heating with Enhanceable Ecological Properties
The existent scientific hypotheses of influence of magnetic-field are analysed on the molecules of water, features magnetic water that can be used in many spheres of vital functions, power engineering specialists etc. Ap...
The Analysis оf Action оf Coulomb аnd Centrifugal Forces оn а Mote іn а Cyclone with Direct-Flow Elements
The design of the combined direct-flow cyclone where centrifugal and electronic mechanisms of separation of dust are combined is presented in article. The given equations for calculation Coulomb and centrifugal forces, a...
Effect of Candles Burning on Ventilation of Premises
At present, the use of different candles in the house has increased significantly to create a pleasant environment. At the same time, from an energy point of view, it is an attempt to reconstruct and create buildings as...
Features of Fluidization of Binary Systems in the Furnaces of a Fluidized Bed
In this paper, we analyzed the characteristics of fluidization of binary systems – wood waste-inert material. Experimental and theoretical study of the hydrodynamics of polydisperse materials. As a result of processing o...
Parameters of a Heat Supply System at a Lower Temperature Chart
In the current Ukrainian economic situation, operation of heat supply systems is under low temperature of the heatingsystem water. The higher temperature chart of 95/70°С is inexpedient because of high cost of fuel. The...