Centrifuge tests on strip footings on sand with a weak layer

Journal Title: Geotechnical Research - Year 2017, Vol 4, Issue 1

Abstract

Tests on small-scale physical models of a strip footing resting on a dense sand bed containing a thin horizontal weak soil layer were carried out at normal gravity (1g). The results, reported in a companion paper, point out that the weak layer plays an important role in the failure mechanism and the ultimate bearing capacity of the footing if it falls within the ground volume relevant to the behaviour of the sand–footing system. The same problem was also investigated by means of centrifuge tests on reduced-scale models at 25g and 40g. The results of these tests, reported and discussed in this paper, confirm that failure mechanisms are governed substantially by the presence of the weak layer if its depth does not exceed a critical value and highlight marked scale effects involving the ultimate bearing capacity related essentially to the mean equivalent stress level in the soil beneath and around the footing. Equivalent bearing capacity factors, N f , for footings on a dense sand bed containing a thin weak layer are derived from experimental results and are proposed in the paper.

Authors and Affiliations

Keywords

Related Articles

Measurement, interpretation and recommended use of laboratory strength properties of fibrous peat

Peat deposits are complex natural formations encountered in many geographical areas. Peat itself is considered as a challenging geomaterial, with many aspects of its behaviour seemingly remaining enigmas. This state-of-t...

Behaviour of MH silts with varying plasticity indices

It is important for geotechnical engineers to understand the intrinsic and mechanical behaviour of silt as it is presently recognised that there exist gaps in understanding its fundamental behaviour. The behaviour of kao...

Centrifuge tests on strip footings on sand with a weak layer

Tests on small-scale physical models of a strip footing resting on a dense sand bed containing a thin horizontal weak soil layer were carried out at normal gravity (1g). The results, reported in a companion paper, point...

Rapid remediation using polyurethane foam/resin grout in Malaysia

Rapid remediation using polyurethane foam/ resin grout in Malaysia

Mechanical behaviour of sand stabilised with colloidal silica

The response of sand stabilised with colloidal silica aqueous gel is examined in the laboratory, under direct shear, triaxial and normal compression loading, in comparison to that of untreated sand of similar density to...

Download PDF file
  • EP ID EP292345
  • DOI 10.1680/jgere.16.00021
  • Views 53
  • Downloads 0

How To Cite

(2017). Centrifuge tests on strip footings on sand with a weak layer. Geotechnical Research, 4(1), 47-64. https://europub.co.uk/articles/-A-292345