CFD Analysis of Air and Steam in a Rectangular Channel Having Parallel RIBS

Abstract

A Computational fluid dynamics analysis of air and steam cooling a rectangular channel with parallel ribs. The effects of Reynolds numbers (Re), rib spacing ratio (P/e), and rib angles (α) on steam and air convective heat transfer were obtained. Heat transfer distribution is done for rib spacing ratio (P/e)=8, 10 and 12 and ribs angle 900 to 450.The heat transfer enhancement of both air and steam increased with decreasing the rib angle from 90° to 45° . Although both air and steam flow are similar to each other, the steam flow obtains a high convective heat transfer enhancement capability. For the corresponding degrees the heat transfer coefficient decreases and a study is made on rectangular duct having acute and right angled ribs based on a backflow. Study is made on P/e = 8 having higher strength when compared with P/e = 12 is analyzed based on heat transfer of air and steam flow through a rectangular duct. The modelling has be done on the Creo parametric 2.0 software and to get the exact mesh of the duct the meshing was done in Hypermesh and the analysis were done in CFD Fluent software.

Authors and Affiliations

S. Srinivasan, A. U. Jeevan Kumar

Keywords

Related Articles

Raspberry Pi and Image Processing Based Electronic Voting Machine (EVM)

Electronic voting machine has already been developed and widely used in many developed countries. But most of them use Radio Frequency ID. In developing countries RFID for each person does not exist. And using RFID is s...

Limnological investigations of Amara Pond (Raipur Karchuliyan) Rewa (M.P.)

Present investigations were carried out on the limnological aspects of Amara pond in district Rewa. Many of the parameters were found below the permissible limits for drinking water as suggested by WHO. A total of 16 pa...

Analysis of a RC Building Frame on Terrain Considering Different Seismic Zone

This research paper consists on “Seismic Analysis of Building frames on Hilly Terrain” as per I.S. 1893 part1. (Structures) on sloping ground require more importance in analysis than those on plane strata. Structures on...

Object Collision Avoidance with Train Using Android System

Railways are providing Eco-Friendly transport system for the mankind. Train accidents can happen very often due to safety violations which results from human errors or limitations in the operation of the existing system...

Bending Analysis of Functionally Graded Beam by Refined Theory

A refined theory is applied for the flexural analysis of functionally graded beams. The present study involves four unknown variables which are five in first order shear deformation theory or any other higher order theo...

Download PDF file
  • EP ID EP22768
  • DOI -
  • Views 228
  • Downloads 3

How To Cite

S. Srinivasan, A. U. Jeevan Kumar (2016). CFD Analysis of Air and Steam in a Rectangular Channel Having Parallel RIBS. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 4(11), -. https://europub.co.uk/articles/-A-22768