Changes in whole body and local muscle oxygen consumption during prolonged cycling
Journal Title: Journal of Science and Cycling - Year 2014, Vol 3, Issue 2
Abstract
Background: Cycling efficiency is a measure of the power output to power input and is a key determinant of cycling performance (Hopker et al., 2013: Journal of Applied Physiology, 115, 723-729). However, the determinants of cycling efficiency are yet to be fully elucidated. Past research has demonstrated that the majority of energetic cost that arises from endurance exercise can be attributed to the exercising muscle (Poole et al., 1992: Journal of Applied Physiology, 72, 805-810), however cycling efficiency is commonly determined by measuring pulmonary oxygen consumption. Purpose: This study aimed to investigate whether cycling efficiency calculated from pulmonary oxygen uptake was reflective of indices of local muscle oxygenation and oxygen consumption measured by near-infrared spectroscopy.Methods: Thirteen competitive cyclists (30 ± 14 years, 173 ± 10 cm, 73 ± 2 mL.kg-1.min-1) performed a 120-minute bout of steady state cycling at 60 % maximum minute power (MMP), determined from a preceding maximal incremental exercise test performed on a separate occasion. Measurements of expired air were taken at minute 5 and then every 30 minutes throughout the rest of the steady state trial. Power input was calculated from the measured VO2 and its energetic equivalent according to the nonprotein respiratory quotient. Power output was recorded as the average power output over the gas collection time. Cycling Gross Efficiency (GE) was calculated as the product of work accomplished / energy expended x 100%. Near-infrared spectroscopy was used to assess the Tissue Saturation Index (TSI%), oxygenated hemoglobin (O2Hb), deoxygenated hemoglobin (HHb), total hemoglobin (tHb) and muscle oxygen consumption (mVO2) of the Vastus Lateralis muscle. NIRS measurements were taken at the same time as sampling of expired gases. To normalize the concentration changes in the NIRS signal, a 2-minute resting baseline was recorded prior to the cycling bout, which was then subtracted from all the NIRS measurements (except TSI%). Data were analysed using repeated measures ANOVA to assess changes over time. Results: As shown in Figure 1, GE significantly decreased over the duration of the steady state cycling trial (p=0.002), as did TSI% (p<0.001). O2Hb increased over time, but this was not significant (p=0.332). Both HHb and tHb significantly increased over time (p<0.01). There was a mean increase in mVO2 over the first 30 minutes of exercise, but then a progressive decrease for the remaining 90 minutes of the trial. However changes were not significant (p=0.289). Discussion: Tissue oxygenation of the Vastus Lateralis muscle significantly reduced over the 2-hour bout of cycling, which was mirrored by reductions in GE. The largest reductions in TSI% and GE occurred during the first 30 minutes of the trial, which is also reflected in the HbO2 concentration. tHb increased over the 2-hours cycling suggesting increased central delivery to the working muscle in an attempt to maintain the level of oxygen availability to the working muscle. However, it can be seen from the TSI(%) and mVO2 that tissue oxygenation and muscle oxygen consumption both decline over the 2–hour period of cycling. Conclusion: Reductions in muscle tissue oxygenation and mVO2 during 2-hours of cycling at mirrored by GE calculated from whole body oxygen consumption.
Authors and Affiliations
C O’Grady| Endurance Research Group, School of Sport and Exercise Sciences, University of Kent, United Kingdom, B Pageaux| Endurance Research Group, School of Sport and Exercise Sciences, University of Kent, United Kingdom, JG Hopker| Endurance Research Group, School of Sport and Exercise Sciences, University of Kent, United Kingdom
The reliability of performance during computer-simulated varying gradient cycling time trials
Ergometer based time trials are commonly used to assess performance changes due to training or other interventions. This investigation establishes the reliability of a novel computer simulated cycling time trial. Ninetee...
Orthotic insoles show effects on knee kinematics during pedaling in recreational cyclists
Orthotic insoles in cycling shoes are an intervention used to correct pedaling mechanics in riders, which has received little attention in the literature. This study was designed to test the hypothesis that the use of or...
The effect of aerodynamic characteristics on the drafting effect in track cycling
Since the aim of the men’s team pursuit is to accomplish a distance of 4000m as fast as possible, reducing aerodynamic drag by means of drafting can attribute in achieving this goal. Broker et al.1 quantified the average...
Analysis of performances at the ‘Ironman Hawaii triathlon’ and its qualifier events with respect to nationality
Ergometers and stationary bicycle trainers are commonly used in laboratories to simulate overground riding. Missing from such instrumentation, however, is any demand for balance and the fraction of the metabolic cost ass...
O2score device: analysis of the kinetics of recovery after exercise
The O2Score system was recently developed as a mobile device able to measure the quantity of antioxidants in the body. Since the quantity of antioxidants is modified during effort (to provide a defense system against fre...